Certification Record
LC1227412
H2Scan Corporation
2016-01-25
California
United States
P/N 50000021 R3, HY-ALERTA Model 1600 Series, HY-OPTIMA Model 1700 Series
29.260.20
- Barrier P/N 50000021 R3 (To be used to limit power to the HY-ALERTA Model 1600 Series and HYOPTIMA Model 1700 Series covered in Part B of this report to an intrinsically safe level)
- CSA Standard Ratings: [Ex ib] IIC Gb
- UL Standard Ratings: Class I Zone 1 [AEx ib] IIC Gb
- Um = 250 V,
- Uo = 11.5 Vdc
- Io = 3.27 Adc
- Po = 9.41 W
- Ci = 0
- Li = 0
- Co = 1.64uF
- Lo = 3.3uH
- Lo/Ro = 29 uH/ohms
- Process Monitor HY-ALERTA Model 1600 Series & Process Monitor HY-OPTIMA Model 1700 Series (to be used with associated IS Shunt Safety Assembly)
- CSA Standard Ratings: Ex ia II H2, d+d IIB T3 Ga and Ex ib II H2, ib d IIB T3 Gb
- UL Standard Ratings: Class I Zone 0 AEx ia II H2, d+d IIB T3 Ga and Class I Zone 1 AEx ib II H2, ib d IIB T3 Gb
- J1 Pins 2 & 3 (power supply)
- Ui = 11.5 V
- Ii = 3.27 A
- Pi = 9.41 W
- The equivalent parameters are:
- CI = 0
- LI = 0
- J1 Pins 4 & 5 (4-20 mA loop)
- UI = 26.7 V
- Ii = 91 mA
- Pi = 0.611 W
- The equivalent parameters are:
- CI = 68.2 nF
- LI = 0
- J2 Pins 1 & 2 and 3 & 4 (Rx and Tx)
- UI = 3.7 V
- Ii = 225 mA
- Pi = 206 mW
- The equivalent parameters are:
- CI = 0
- LI = 0
- Uo = 5.9 V
- Io = 238 mA
- Po = 0.35 W
- Co = 1000 uF
- Lo = 2.5 mH
- Lo/Ro = 404 uH/ohms
- CAN/CSA-E60079-11:2011
- UL 60079-11(Ed.6): 2013
- None
General Note:
- Project no.: 12618
- LC Listing Report no.: 9001-1S_Rev.3
- LC Certificate no.: 9001-1S_Rev.3