LC Clients

Certification Record

LC1227412
H2Scan Corporation
2016-01-25
California
United States
P/N 50000021 R3, HY-ALERTA Model 1600 Series, HY-OPTIMA Model 1700 Series
29.260.20
  • Barrier P/N 50000021 R3 (To be used to limit power to the HY-ALERTA Model 1600 Series and HYOPTIMA Model 1700 Series covered in Part B of this report to an intrinsically safe level)
  • CSA Standard Ratings: [Ex ib] IIC Gb
  • UL Standard Ratings: Class I Zone 1 [AEx ib] IIC Gb
    • Um = 250 V,
    • Uo = 11.5 Vdc
    • Io = 3.27 Adc
    • Po = 9.41 W
    • Ci = 0
    • Li = 0
    • Co = 1.64uF
    • Lo = 3.3uH
    • Lo/Ro = 29 uH/ohms
  • Process Monitor HY-ALERTA Model 1600 Series & Process Monitor HY-OPTIMA Model 1700 Series (to be used with associated IS Shunt Safety Assembly)
  • CSA Standard Ratings: Ex ia II H2, d+d IIB T3 Ga and Ex ib II H2, ib d IIB T3 Gb
  • UL Standard Ratings: Class I Zone 0 AEx ia II H2, d+d IIB T3 Ga and Class I Zone 1 AEx ib II H2, ib d IIB T3 Gb
  • J1 Pins 2 & 3 (power supply)
    • Ui = 11.5 V
    • Ii = 3.27 A
    • Pi = 9.41 W
  • The equivalent parameters are:
    • CI = 0
    • LI = 0
  • J1 Pins 4 & 5 (4-20 mA loop)
    • UI = 26.7 V
    • Ii = 91 mA
    • Pi = 0.611 W
  • The equivalent parameters are:
    • CI = 68.2 nF
    • LI = 0
  • J2 Pins 1 & 2 and 3 & 4 (Rx and Tx)
    • UI = 3.7 V
    • Ii = 225 mA
    • Pi = 206 mW
  • The equivalent parameters are:
    • CI = 0
    • LI = 0
    • Uo = 5.9 V
    • Io = 238 mA
    • Po = 0.35 W
    • Co = 1000 uF
    • Lo = 2.5 mH
    • Lo/Ro = 404 uH/ohms
  • CAN/CSA-E60079-11:2011
  • UL 60079-11(Ed.6): 2013
  • None

General Note:

  • Project no.: 12618
  • LC Listing Report no.: 9001-1S_Rev.3
  • LC Certificate no.: 9001-1S_Rev.3
Go to Top