LC Clients

Certification Record

LC1231035
Halogen Systems, Inc.
2023-11-03
Nevada
United States
EX-P-HT4, EX-P-STD, EX-P-STD2
  • Oxidant sensor made of 316 stainless steel certified flameproof enclosure
  • Model Nos.: EX-P-HT4 (AKA: EX-P-HT6; SWN-HT-EX), EX-P-STD, EX-P-STD2
  • Part Nos.: 14-00084-0D M2, 14-00084-0E M2, 14-00084-0F M2, 14-00084-0G, 14-00084-0H
  • ATEX Rating:
    • Ex db ib IIC T5 Gb
    • IP56
    • -20 °C ≤ Tamb ≤ +55 °C
    • 24 VDC, 350mA (Um=250V)
  • ATEX Directive: 2014/34/EU
    • EN 60079-1:2014
    • EN 60079-11:2012
  • None

General Note:

  • Project no.: LV-15922A
  • ATEX Report no.: 11.00.15922-1_Rev.0
  • ATEX EU Type Certificate no.: LC23ATEX15922A-1(X), Issue 0
Issued by: Marin Banu Reviewed By: Kavinder Dhillon, Eng.L.
Title: Project Engineer Title: Certification Manager
Date: August 18, 2023 Date: November 3, 2023

 