Certification Record
LC1236562
Ergosun Holdings, LLC
2024-02-01
Iowa
United States
Ergosun 55W, Ergosun 50W
27.160
- Photovoltaic Module
- Model Nos.: Ergosun 55W & Ergosun 50W
- Ratings:
- Ergosun 55W:
- Open Circuit Voltage (Voc): 14.5 V
- Short Circuit Current (Isc): 5.30 A
- Maximum Series Overcurrent Protection: 20 A
- Voltage at Maximum Power (Vmp): 12 V
- Current at Maximum Power (Imp): 4.83 A
- Maximum Power (Pw): 55.0 W
- Maximum System Voltage: 600 VDC
- Nominal Operating Cell Temperature (NOCT): 25°C to 55°C
- Operating Temperature Range: -40°C to 85°C
- Roof Covering Material Fire Class Rating: Class A
- Ergosun 50W:
- Open Circuit Voltage (Voc): 14.5 V
- Short Circuit Current (Isc): 4.58 A
- Maximum Series Overcurrent Protection: 20 A
- Voltage at Maximum Power (Vmp): 12 V
- Current at Maximum Power (Imp): 4.17 A
- Maximum Power (Pw): 50.0 W
- Maximum System Voltage: 600 VDC
- Nominal Operating Cell Temperature (NOCT): 25°C to 55°C
- Operating Temperature Range: -40°C to 85°C
- Roof Covering Material Fire Class Rating: Class A
- Ergosun 55W:
Note: Electrical ratings measured in standard test conditions (STC) of 1000 W/m², AM 1.5 spectrum, and 25°C
- CAN/CSA-C22.2 NO. 61730-1:2019
- CAN/CSA-C22.2 NO. 61730-2:2019
- UL 61730-1:2022
- UL 61730-2:2022
- CAN/CSA-C22.2 NO. 61215-1:2018
- CAN/CSA-C22.2 NO. 61215-2:2018
- UL 61215-1:2021
- UL 61215-2:2021
- Maximum system voltage of 600VDC
General Notes:
- Project no.: LV-16101
- LC Listing Report no.: 10.02.16101-1_Rev.0
- LC Certificate no.: LC16101-1