Certification Record
LC1231551
SENKO Co., Ltd.
2024-05-09
Gyounggi-do
Korea, Republic of
SP-MGTP-P0, SP-MGTP-N0, SP-MGTP-N1, SP-MGTP-N2, SP-MGTP-00
11.080.10
- Portable Multi Gas Detector
- Model Nos.:
- SP-MGTP-P0
- SP-MGTP-N0
- SP-MGTP-N1
- SP-MGTP-N2
- SP-MGTP-00
- Ratings:
- Battery powered, using preapproved battery 3.7V, 4000mAh, max charging voltage 6.3V.
Models Marking SP-MGTP-P0 Series Ex da ia IIC T4 Ga Class I, Division 1, Groups A, B, C, and/or D, T4 Class I, Zone 0, AEx da ia IIC T4 Ga Ex da ia IIB T4 Ga Class I, Division 1, Groups C, and/or D, T4 Class I, Zone 0, AEx da ia IIB T4 Ga SP-MGTP-N0 Series Ex ia IIC T4 Ga Class I, Division 1, Groups A, B, C, and/or D, T4 Class I, Zone 0, AEx ia IIC T4 Ga Ex ia IIB T4 Ga Class I, Division 1, Groups C, and/or D, T4 Class I, Zone 0, AEx ia IIB T4 Ga SP-MGTP-N1 Series Ex db ia IIC T4 Gb Class I, Division 1, Groups A, B, C, and/or D, T4 Class I, Zone 1, AEx db ia IIC T4 Gb Ex db ia IIB T4 Gb Class I, Division 1, Groups C, and/or D, T4 Class I, Zone 1, AEx db ia IIB T4 Gb SP-MGTP-N2 Series Ex db ia IIC T4 Gb Class I, Division 1, Groups A, B, C, and/or D, T4 Class I, Zone 1, AEx db ia IIC T4 Gb Ex db ia IIB T4 Gb Class I, Division 1, Groups C, and/or D, T4 Class I, Zone 1, AEx db ia IIB T4 Gb SP-MGTP-00 Series Ex ia IIC T4 Ga Class I, Division 1, Groups A, B, C, and/or D, T4 Class I, Zone 0, AEx ia IIC T4 Ga Ex ia IIB T4 Ga Class I, Division 1, Groups C, and/or D, T4 Class I, Zone 0, AEx ia IIB T4 Ga
- Battery powered, using preapproved battery 3.7V, 4000mAh, max charging voltage 6.3V.
- CSA C22.2 No. 60079-0:2019 / UL 60079-0 – Edition 7
- CSA C22.2 No. 60079-1:16(R2021) / UL 60079-1 – Edition 7
- CSA C22.2 No. 60079-11:14(R2023) / UL 60079-11 – Edition 6
- UL 913 – Edition 8
- CAN/CSA-C22.2 No. 61010-1-12 (R2022) / UL 61010-1 – Edition 3
- The equipment shall only be carried and must not be laid down unattended.
- The IR communication functions shall only be used in a safe (non-hazardous) area where there is no risk of explosion or fire.
- The equipment shall only be charged while in the non-hazardous area, using a charger specifically supplied for use with the unit (for example part number ICP12-060-1200D, manufactured by Shenzhen Shi Ying Yuan Electronics Co, LTD), approved as SELV or Class 2 equipment against IEC 60950, IEC 61010-1 or an equivalent IEC standard. The maximum voltage and current from the charger shall not exceed 6.3 Vdc plus tolerances and 1.2 A respectively and shall be further limited by the charging system to Um = 6.3 Vdc. The ambient temperature during charging shall be in the range 0 °C to 45 °C.
General Note:
- Project no.: T-22331
- LC Listing Report no.: 11.03.22331-1_Rev.0
- LC Certificate no.: LC22331-1