Certification Record
                    LC1225077                
            
                    Acucraft Fireplaces                
            
                    2024-06-28                
            
                    Minnesota                
            
                    United States                
            
                    Blaze Series                
            
                    97.100.20                
            - Vented Decorative Gas Appliances
 - Series: Blaze Series
 - Models:
- Single Sided Models
 - Panoramic Models
 - Peninsula Models
 - Front Left Models
 - Front Right Models
 - Four Sided Models
 - See-Through Models
 - Indoor/Outdoor Models
 
 
Individual model numbering designation as follows: A-XX-YY-ZZ
- XX denotes width and shall be between 3 and 10
 - YY denotes model type
 - ZZ denotes height and shall be between 20 and 80
 
- Ratings:
- All Models – Fuel Input at 3.5” w.c. Natural Gas manifold pressure and 10” w.c. Propane manifold pressure:
- Min: 44k BTU/hr – Max: 198k BTU/hr
 
 - All Models – Electrical Ratings: 120 Vac, 60 Hz, 2 Amps max
 
 - All Models – Fuel Input at 3.5” w.c. Natural Gas manifold pressure and 10” w.c. Propane manifold pressure:
 
- ANSI Z21.50-2019 / CSA 2.22-2019
 - ANSI Z21.97-2017(R2022) / CSA 2.41-2017(R2022)
 
Note: ANSI Z21.97-2017(R2022) / CSA 2.41-2017(R2022) is only applicable to Indoor/Outdoor (I/O) models of the series.
- Shall be connected to a listed venting system as specified by the manufacturer and in accordance with local codes.
 - Not to be used with solid fuel.
 
General Notes:
- Project No.: LV-16090
 - LC Listing Report No.: 50.02.16090-13_Rev0
 - LC Certificate No.: LC16090-13