CGAS-D-aaaa-bbbb-oo (digital gas detector), CGAS-A-aaaa-bbbb-oo (analog gas detector)
29.240.30, 13.320
  • Gas Detector
  • Model Nos.:
    • CGAS-D-aaaa-bbbb-oo (digital gas detector)
    • CGAS-A-aaaa-bbbb-oo (analog gas detector)

Where:

The first group of four characters “aaaa” indicates the gas (sensor) of channel 1 and the second group of “bbbb” indicate the gas (sensor) of channel 2 (if included).

As of April 2018, possible values include but are not limited to:

(blank)              no sensor

NH3                  Ammonia Sensor

LCO                  Carbon Monoxide Sensor

CL2                   Chlorine Sensor

CLO2                Chlorine Dioxide Sensor

C2H4                Ethylene Sensor

EETO                Ethylene Oxide Sensor

F2                     Fluorine Sensor

CH20                Formaldehyde Sensor

EH2                  Hydrogen Sensor

H2S                  Hydrogen Sulphide Sensor

HCL                  Hydrogen Chloride Sensor

HCN                 Hydrogen Cyanide Sensor

HF                    Hydrogen Fluoride sensor

NO                   Nitric Oxide sensor

NO2A               Nitrogen Dioxide sensor

O2                    Oxygen sensor

O3                    Ozone Sensor

PH3                  Phosphine Sensor

SIH4                 Silane Sensor

SO2                  Sulphur dioxide sensor

CO2                  Carbon Dioxide sensor

CH2                  Hydrogen Sensor

CCH4               Methane sensor

CC3H8              Propane Sensor

SPL                  TVOC PID sensor (0-30ppm)

SPH                  TVOC PID sensor (0-300ppm)

 

The characters ‘oo’ indicate possible options. Values are:

IH         Internal header for cold environment application down to -40C

S           Splash Guard (not available with CL2, HCL or O3)

RHT     Relative Humidity and temperature sensor

RLY      Internal SPDT relay rated 30V @ 2A max (not available with CO2)

(blank)  Indicating that no options are included on the particular unit

  • Ratings : 16 – 30Vdc 3W / 12 – 27Vac 50-60Hz 3VA / Class 2
  • CSA-C22.2 No. 205-12
  • UL 508 (Edition 18): 2018
  • Permanently connected, wall mount, pollution degree 2 and intended to be used indoors in ambient temperature of -40°C to 40°C.

General Note:

  • Project no.: 17037D
  • LC Listing Report no.: 10.00.17037-1_Rev.D
  • LC Certificate no.: LC17037-1