Certification Record
                    LC1230773                
            
                    Eco Heating Systems Groningen B.V.                
            
                    2024-07-25                
            
                    Groningen                
            
                    Netherlands                
            
                    DB-80-CH, DB-90-CO, DB-100-CH, DB-120-CH, DB-150-CO, DB-150-CH, DB-180-CH, DB-200-CO                
            
                    27.060.20, 27.060.30                
            - Instantaneous or Circulating Tank Water Heater
 - Model Nos.: DB-80-CH, DB-90-CO, DB-100-CH, DB-120-CH, DB-150-CO, DB-150-CH, DB-180-CH, DB-200-CO
 - Ratings:
Model DB-80-CH DB-90-CO DB-100-CH MAX MIN MAX MIN MAX MIN NG MBTU/HR 80 8 80 9 100 10 LPG MBTU/HR 80 8 80 9 100 10 Fan Speed (RPM) – NG 7450 1350 8100 1550 6750 1300 Fan Speed (RPM)- LPG 6850 1400 7700 1550 6450 1400 Thermal Efficiency (%) per ANSI/ASHRAE 103-2017 95.6(NG) 95.7 (NG) 95.4 (NG) Thermal Efficiency (%) per CAN/CSA P.2 – 13 (R 2017) 95.7 95.7 95.5 Electrical: 120 VAC, 60 Hz, less than 12 Amp Model DB-120-CH DB-150-CO DB-150-CH MAX MIN MAX MIN MAX MIN NG MBTU/HR 120 12 120 15 150 15 LPG MBTU/HR 120 12 120 15 150 15 Fan Speed (RPM) – NG 6800 1250 8000 1400 7100 1300 Fan Speed (RPM)- LPG 6900 1350 8300 1550 7150 1450 Thermal Efficiency (%) per ANSI/ASHRAE 103-2017 95.1(NG) 95.0 (NG) 95.4 (NG) Thermal Efficiency (%) per CAN/CSA P.2 – 13 (R 2017) 95.2 95.0 95.5 Electrical: 120 VAC, 60 Hz, less than 12 Amp Model DB-180-CH DB-200-CO MAX MIN MAX MIN NG MBTU/HR 180 18 180 20 LPG MBTU/HR 180 18 180 20 Fan Speed (RPM) – NG 6900 1300 7600 1400 Fan Speed (RPM)- LPG 6900 1350 7600 1450 Thermal Efficiency (%) per ANSI/ASHRAE 103-2017 95.2(NG) 95.3 (NG) Thermal Efficiency (%) per CAN/CSA P.2 – 13 (R 2017) 95.2(NG) 95.3(NG) Electrical: 120 VAC, 60 Hz, less than 12 Amp  
- ANSI Z21.13-2017/ CSA 4.9-2017
 - CAN/CSA-P.2-13 (R 2017)
 
- Suitable for use with Natural Gas or Propane, for indoor use only.
 - Not to be used with solid fuel.
 - The ventilation of the boiler room must meet local and national standards and regulations, regardless of the selected supply of fresh air to the boiler.
 - The flue gas system must be per the installation manual.
 - Unit must be installed with a certified pressure relief valve supplied by the manufacturer as per instructions manual.
 
General Note:
- Project no.: 17851A
 - LC Listing Report no.: 50.00.17851-2_Rev.A
 - LC Certificate no.: LC17851-2