Certification Record
                    LC1237496                
            
                    Sunlight-Window Mfg. Ltd.                
            
                    2024-08-12                
            
                    British Columbia                
            
                    Canada                
            
                    SW-FW-IGXX                
            
                    91.060.50                
            - TP Series Triple Glazed Fixed Window
 - Model code SW-FW-IGXX
 - Performance Class/ Performance Grade Rating – Class LC – PG60
 - Thermal simulation performed for four triple glazing option.
 
Legend for Coding System and Energy Performance Values:
- ‘XX’ is the applicable glazing option (4 options currently as shown below)
 
Glazing Options:
- Option 01: LoE² 270 on 3mm Clear (Surface #2, ε = 0.035) / 12.7mm Air (10%) – Argon (90%) Mix / LoE 180 on 3mm Clear (Surface #4, ε = 0.068) / 12.7mm Air (10%) – Argon (90%) Mix / i89 on 3mm Clear (Surface #6, ε = 0.149) (Total Thickness = 34.4mm)
 - Option 02: LoE³ 366 on 3mm Clear (Surface #2, ε = 0.02) / 12.7mm Air (10%) – Argon (90%) Mix / LoE 180 on 3mm Clear (Surface #4, ε=0.068) / 12.7mm Air (10%) – Argon (90%) Mix / i89 on 3mm Clear (Surface #6, ε = 0.149) (Total Thickness = 34.4mm)
 - Option 03: LoE² 270 on 3mm Clear (Surface #2, ε = 0.035) / 12.7mm Air (10%) – Argon (90%) Mix / Generic Clear Glass / 12.7mm Air (10%) – Argon (90%) Mix / i89 on 3mm Clear (Surface #6, ε = 0.149) (Total Thickness = 34.4mm)
 - Option 04: LoE² 270 on 3mm Clear (Surface #2, ε = 0.035) / 12.7mm Air (10%) – Argon (90%) Mix / LoE 180 on 3mm Clear (Surface #4, ε = 0.068) / 12.7mm Air (10%) – Argon (90%) Mix / Generic Clear Glass (Total Thickness = 34.4mm)
 
Thermal Simulation Results:
- SW-FW-IG01: U factor: 0.8; Solar Heat Gain Coefficient: 0.28; Visible Transmittance: 0.52; Air Leakage: 0.2; Energy Rating: 38.
 - SW-FW-IG02: U factor: 0.79; Solar Heat Gain Coefficient: 0.21; Visible Transmittance: 0.48; Air Leakage: 0.2; Energy Rating: 34.
 - SW-FW-IG03: U factor: 1.0; Solar Heat Gain Coefficient: 0.29; Visible Transmittance: 0.54; Air Leakage: 0.2; Energy Rating: 34
 - SW-FW-IG04: U factor: 0.89; Solar Heat Gain Coefficient: 0.28; Visible Transmittance: 0.53; Air Leakage: 0.2; Energy Rating: 36.
 
- AAMA/WDMA/CSA 101/I.S.2/A440:22
 - CSA A440S1:19
 - CSA A440.2:22
 
- Products are certified for Canadian Market only
 
General Note:
- Project no.: 22232
 - LC Listing Report no.: 40.00.22232-1_Rev.0
 - LC Certificate no.: LC22232-1