Certification Record
                    LC1228218                
            
                    Gasmaster Industries                
            
                    2024-10-16                
            
                    British Columbia                
            
                    Canada                
            
                    GMI / GMI DF Series, HC Series                
            
                    27.060.20                
            - Gas Fired Boilers and Water Heaters
 - Model No.: GMI / GMI DF Series and HC Series
 - Ratings:
Model Tube Size (inch) Burner Burner Model Low Rating (MBH) Hi Rating (MBH) Manifold Pressure Low Input (inwc) Manifold Pressure High Input (inwc) Ignition Type Electrical Rating (HP/V/Φ/A/Hz) GMI / GMI DF 1M 1.25 Gasmaster GMI 1M Premix 400 1000 -0.2 -0.2 Interrupted Pilot /120/1/8.5/50-60 GMI / GMI DF 1.5 1.25 Gasmaster GMI 1.5M Premix 400 1500 -0.2 -0.2 Interrupted Pilot /120/1/16/50-60, 
/240/1/12/50-60GMI / GMI DF 2M 1.25 Gasmaster GMI 2M Premix 400 2000 -0.2 -0.2 Interrupted Pilot /120/1/16/50-60, /240/1/12/50-60
GMI / GMI DF 3M 1.25 Gasmaster GMI 3M Premix 400 3000 -0.2 -0.2 Interrupted Pilot /120/1/16/50-60, /240/3/12/50-60
GMI / GMI DF 4M 1.25 Gasmaster GMI 4M Premix 500 4000 -0.2 -0.2 Interrupted Pilot 3.2/480/3/5/50-60 GMI / GMI DF 5M 1.25 Gasmaster GMI 5M Premix 500 5000 -0.2 -0.2 Interrupted Pilot 3.2/480/3/5/50-60 GMI / GMI DF 6M 1.25 Gasmaster GMI 6M Premix 600 6000 -0.2 -0.2 Interrupted Pilot 3.2/480/3/5/50-60 GMI / GMI DF 8M 1.25 Gasmaster GMI 8M Premix 1000 8000 -0.2 -0.2 Interrupted Pilot /480/3/8/50-60 HC 600 1” Gasmaster GMI 1M Premix 400 600 -0.2 -0.2 Interrupted Pilot ** 0.75-/120/1/8.5/50-60 HC 1000 1” Gasmaster GMI 1M Premix 400 1000 -0.2 -0.2 Interrupted Pilot ** 0.75-/120/1/8.5/50-60 HC 1500 1” Gasmaster GMI 1.5M Premix 400 1500 -0.2 -0.2 Interrupted Pilot ** /120/1/16/50-60, /240/1/12/50-60 HC 2000 1” Gasmaster GMI 2M Premix 400 2000 -0.2 -0.2 Interrupted Pilot ** /120/1/16/50-60, /240/1/12/50-60 HC 2500 1” Gasmaster GMI 3M Premix 400 2500 -0.2 -0.2 Interrupted Pilot ** /120/1/16/50-60, /240/1/14/50-60/240/3/14/50-60 HC 3000 1” Gasmaster GMI 3M Premix 400 3000 -0.2 -0.2 Interrupted Pilot ** 3/208-230/3/9/60, 3/460/3/4.5/60 **Alternate Direct Ignition
 
- ANSI Z21.13 – CSA 4.9 – 2022
 - ANSI Z21.10.3 – CSA 4.3 – 2019
 - CSA 2.17 – 2017
 
- Indoor use only.
 - Suitable for use with Natural Gas or Propane.
 - Not suitable for direct venting systems.
 - Not suitable to be used for installation in Recreational Vehicles.
 - Suitable for vertical venting only
 
General Note:
- Project no.: 21419
 - LC Listing Report no.: 50.00.21419-1_Rev.0
 - LC Certificate no.: LC21419-1