Certification Record
LC1234167
ESG Solutions
2024-08-23
Ontario
Canada
P/N JB-4430-1305-6 CS
- Micro-Seismic Instrumentation Box
- Model No.: P/N JB-4430-1305-6 CS
- Serial No.: S/N JB-TAQA-2024-0086-01
- Ratings:
- CE2815 Ex II 2 G Ex db IIA T3 Gb
- -40°C ≤ Tamb ≤ 45° C
- Electrical ratings: 220V, 4A
- EN 60079-0:2018
- EN 60079-1:2014
- The power supply cable used to be suitable certified for Ex db and Zone 1 installation and acceptable to Local Authority Having Jurisdiction.
- Separate cable entries shall be designated for the intrinsically safe field wiring.
- Individual intrinsically safe circuit components and wiring shall be separated from each other
- The installation shall comply with the intrinsically safe barrier manufacturer’s installation instructions.
- The possibility that non-intrinsically safe field wiring could come in contact with intrinsically safe terminals or wiring shall also be eliminated.
- The clearance distance between bare conductive parts and terminals of intrinsically safe circuits and non-intrinsically safe circuits shall be at least 50 mm or as defined in IEC 60079-11.
- The terminals of intrinsically safe circuits shall be marked for clear identification to differentiate them from the terminals of non-intrinsically safe circuits.
- The clearance distance between bare conductive parts and terminals of connection facilities shall be at least 6 mm between the separate intrinsically safe circuits.
General Note:
- Project no.: T-22347
- ATEX CAT 2 ANNEX V Unit Verification Report no.: 11.03-22347-1_Rev.0
- ATEX EU-Unit Verification Certificate no.: LC24ATEX22347-1X, Issue 0