LC Clients

Certification Record

LC1234796
Polishinterior S.C.
2024-11-26
Krakow
Poland
PI-AD104-IGXX
91.060.50
  • AD104 Inswing Side-Hinged Door
  • Model code PI-AD104-IGXX
  • Performance Class/ Performance Grade Rating – Class CW – PG45
  • Thermal simulation performed for five double- and triple-glazing options.

Legend for Coding System and Energy Performance Values:

  • ‘XX’ is the applicable glazing option (5 options currently as shown below)

Glazing Options:

  • Option 01: 6mm ExtraClear / 18mm 90% Argon / 6mm ClimaGuard Premium2
  • Option 02: 4mm ClimaGuard Premium2 / 18mm 90% Argon / 4 mm ExtraClear / 18mm 90% Argon / 4mm ClimaGuard Premium2
  • Option 03: 6mm ClimaGuard Premium2 / 16mm 90% Argon / 6mm ExtraClear / 16mm 90% Argon / 6mm ClimaGuard Premium2
  • Option 04: 4mm SN70S / 18mm 90% Argon / 4 mm ExtraClear / 18mm 90% Argon / 4mm SN70S
  • Option 05: 6mm SN70S / 16mm 90% Argon / 6 mm ExtraClear / 16mm 90% Argon / 6mm SN70S

Thermal Simulation Results:

  • PI-AD104-IG01: U-Factor (BTU/h-ft2-°F): 0.326; SHGC: 0.358; VT: 0.458; L75: 0.5; ER: 19.
  • PI-AD104-IG02: U-Factor (BTU/h-ft2-°F): 0.243; SHGC: 0.296; VT: 0.416; L75: 0.5; ER: 26.
  • PI-AD104-IG03: U-Factor (BTU/h-ft2-°F): 0.241; SHGC: 0.289; VT: 0.409; L75: 0.5; ER: 26.
  • PI-AD104-IG04: U-Factor (BTU/h-ft2-°F): 0.241; SHGC: 0.183; VT: 0.317; L75: 0.5; ER: 20.
  • PI-AD104-IG05: U-Factor (BTU/h-ft2-°F): 0.239; SHGC: 0.181; VT: 0.311; L75: 0.5; ER: 20.
  • AAMA/WDMA/CSA 101/I.S.2/A440-17
  • CSA A440S1:19
  • CSA A440.2:22
  • Products are certified for Canadian Market only

General Note:

  • Project no.: 21543
  • LC Listing Report no.: 40.00.21543-7_Rev.0
  • LC Certificate no.: LC21543-7
Go to Top