Nav Windows and Doors Ltd
2024-12-11
British Columbia
Canada
Series 9000 Combination Window, Series 9000 Vertical Mullion Assembly, Series 9000 Horizontal Mullion Assembly, Series 9000 Fixed Window, Series 9000 Horizontal Sliding Window
91.060.50
  • Series 9000 Combination Window (Fixed Window + Horizontal Sliding Window)
    • Class R – PG25 – Size tested: 3030 x 2540 mm (119 x 100 in)
  • Series 9000 Vertical Mullion Assembly
    • Class LC – PG25 – Size tested 2540 mm (100.0 in) span/ 1515 mm (59.6 in) TribWd MA
  • Series 9000 Horizontal Mullion Assembly
    • Class LC – PG25 – Size tested 1880 mm (74.0 in) span/ 1270 mm (72.0 in) TribWd MA
  • Series 9000 Fixed Window
    • Model No.: NAV-9000FW-IGXX
    • Class R – PG25 – Size tested: 1150 x 2540 mm (45.3 x 100.0 in) – Type FW
    • Thermal simulation performed for seven double glazing options.
  • Series 9000 Horizontal Sliding Window
    • Model No.: NAV-9000HS-IGXX
    • Class LC – PG25 – Size tested: 1880 x 1750 mm (74.0 x 68.9 in) – Type HS
    • Thermal simulation performed for seven double glazing options.

Glazing Options:

  • Option 01: LoE 180 on 3mm Clear / 12.7mm Argon (90%) / i89 on 3mm Clear
  • Option 02: LoE² 272 on 3 mm Clear / 12.7mm Argon (90%) / i89 on 3mm Clear
  • Option 03: LoE² 272 on 3 mm Clear / 12.7mm Argon (90%) / Generic Clear Glass
  • Option 04: LoE³ 366 on 3mm Clear / 12.7mm Argon (90%) / i89 on 3mm Clear
  • Option 05: LoE 180 on 3mm Clear / 12.7mm Argon (90%) / LoE 180 on 3mm Clear
  • Option 06: LoE³ 366 on 3mm Clear / 12.7mm Argon (90%) / Generic Clear Glass
  • Option 07: LoE² 272 on 3 mm Clear / 12.7mm Argon (90%) / LoE² 272 on 3 mm Clear

Thermal Simulation Results:

Fixed Window

  • IG01: U factor (W/m2-K): 1.32; Solar Heat Gain Coefficient: 0.49; Visible Transmittance: 0.60; Air Leakage: 0.10; Energy Rating: 39.
  • IG02: U factor (W/m2-K): 1.29; Solar Heat Gain Coefficient: 0.32; Visible Transmittance: 0.55; Air Leakage: 0.10; Energy Rating: 30
  • IG03: U factor (W/m2-K): 1.52; Solar Heat Gain Coefficient: 0.33; Visible Transmittance: 0.56; Air Leakage: 0.10; Energy Rating: 26
  • IG04: U factor (W/m2-K): 1.26; Solar Heat Gain Coefficient: 0.21; Visible Transmittance: 0.49; Air Leakage: 0.10; Energy Rating: 24
  • IG05: U factor (W/m2-K): 1.50; Solar Heat Gain Coefficient: 0.48; Visible Transmittance: 0.59; Air Leakage: 0.10; Energy Rating: 35
  • IG06: U factor (W/m2-K): 1.48; Solar Heat Gain Coefficient: 0.22; Visible Transmittance: 0.50; Air Leakage: 0.10; Energy Rating: 20
  • IG07: U factor (W/m2-K): 1.48; Solar Heat Gain Coefficient: 0.30; Visible Transmittance: 0.49; Air Leakage: 0.10; Energy Rating: 25

Horizontal Sliding Window

  • IG01: U factor (W/m2-K): 1.38; Solar Heat Gain Coefficient: 0.38; Visible Transmittance: 0.53; Air Leakage: 1.40; Energy Rating: 29.
  • IG02: U factor (W/m2-K): 1.36; Solar Heat Gain Coefficient: 0.30; Visible Transmittance: 0.50; Air Leakage: 1.40; Energy Rating: 25
  • IG03: U factor (W/m2-K): 1.50; Solar Heat Gain Coefficient: 0.30; Visible Transmittance: 0.51; Air Leakage: 1.40; Energy Rating: 22
  • IG04: U factor (W/m2-K): 1.34; Solar Heat Gain Coefficient: 0.24; Visible Transmittance: 0.48; Air Leakage: 1.40; Energy Rating: 22
  • IG05: U factor (W/m2-K): 1.49; Solar Heat Gain Coefficient: 0.37; Visible Transmittance: 0.53; Air Leakage: 1.40; Energy Rating: 26
  • IG06: U factor (W/m2-K): 1.47; Solar Heat Gain Coefficient: 0.25; Visible Transmittance: 0.48; Air Leakage: 1.40; Energy Rating: 19
  • IG07: U factor (W/m2-K): 1.48; Solar Heat Gain Coefficient: 0.29; Visible Transmittance: 0.48; Air Leakage: 1.40; Energy Rating: 22
  • AAMA/WDMA/CSA 101/I.S.2/A440:22
  • CSA A440S1:19
  • CSA A440.2:22
  • Products are certified for Canadian Market only

General Note:

  • Project no.: 22193
  • LC Listing Report no.: 40.00.22193-1_Rev.0
  • LC Certificate no.: LC22193-1