Certification Record
LC1235136
Onyx Solar Energy S.L.
2024-12-12
Avila
Spain
ONYX G/GM07244, ONYX G/GM07244C, ONYX G/GM07211, ONYX G/GM06044C
27.160
- Monofacial Photovoltaic Modules
- Model Nos.:
- ONYX G/GM07244
- ONYX G/GM07244C
- ONYX G/GM07211
- ONYX G/GM06044C
- Ratings:
- ONYX G/GM07244:
- Open Circuit Voltage (Voc): 48.35 V
- Short Circuit Current (Isc): 9.33 A
- Maximum Series Overcurrent Protection: 17 A
- Voltage at Maximum Power (Vmp): 39.49 V
- Current at Maximum Power (Imp): 8.99 A
- Maximum Power (Pw): 355 W
- Maximum System Voltage: 1000 VDC
- Operating Temperature Range: -40°C to 85°C
- IEC Roof Covering Material Fire Class Rating: Class A
- UL Fire Rating Type: Type 34
- ONYX G/GM07244:
-
- ONYX G/GM07244C:
- Open Circuit Voltage (Voc): 48.25 V
- Short Circuit Current (Isc): 7.35 A
- Maximum Series Overcurrent Protection: 17 A
- Voltage at Maximum Power (Vmp): 39.71 V
- Current at Maximum Power (Imp): 7.14 A
- Maximum Power (Pw): 284 W
- Maximum System Voltage: 1000 VDC
- Operating Temperature Range: -40°C to 85°C
- IEC Roof Covering Material Fire Class Rating: Class A
- UL Fire Rating Type: Type 34
- ONYX G/GM07211
- Open Circuit Voltage (Voc): 48.42 V
- Short Circuit Current (Isc): 8.77 A
- Maximum Series Overcurrent Protection: 17 A
- Voltage at Maximum Power (Vmp): 39.56 V
- Current at Maximum Power (Imp): 8.42 A
- Maximum Power (Pw): 333 W
- Maximum System Voltage: 1000 VDC
- Operating Temperature Range: -40°C to 85°C
- IEC Roof Covering Material Fire Class Rating: Class A
- UL Fire Rating Type: Type 34
- ONYX G/GM07244C:
-
- ONYX G/GM06044C
- Open Circuit Voltage (Voc): 41.14 V
- Short Circuit Current (Isc): 7.74 A
- Maximum Series Overcurrent Protection: 17 A
- Voltage at Maximum Power (Vmp): 33.9 V
- Current at Maximum Power (Imp): 7.38 A
- Maximum Power (Pw): 245 W
- Maximum System Voltage: 1000 VDC
- Operating Temperature Range: -40°C to 85°C
- IEC Roof Covering Material Fire Class Rating: Class A
- UL Fire Rating Type: Type 34
- ONYX G/GM06044C
Note: Electrical ratings measured in standard test conditions (STC) of 1000 W/m², AM 1.5 spectrum, and 25°C.
- CAN/CSA-C22.2 NO. 61730-1:2019
- CAN/CSA-C22.2 NO. 61730-2:2019
- CAN/CSA-C22.2 NO. 61215-1:2018
- CAN/CSA-C22.2 NO. 61215-2:2018
- UL 61730-1:2022
- UL 61730-2:2022
- UL 61215-1:2021
- UL 61215-2:2021
- Maximum system voltage of 1000Vdc
- Maximum overcurrent protection rating of 17A
General Note:
- Project no.: LV-16175
- LC Listing Report no.: 10.02.16175-2_Rev.0
- LC Certificate no.: LC16175-1