Certification Record

LC1237652
Axis Windows Ltd.
2025-05-12
British Columbia
Canada
Axis-9000FW-IGXX, Axis-9000HS-IGXX
91.060.50
  • 9000 Series Composite Window (Fixed Window + Horizontal Sliding Window)
    • Class LC – PG25 – Size tested: 3048 x 2743 mm (120 x 108 in)
  • 9000 Series Vertical Mullion Assembly
    • Class LC – PG25 – Size tested:2743 mm (108 in) span/ 1524 mm (60 in) TribWd MA
  • 9000 Series Horizontal Mullion Assembly
    • Class LC – PG25 – Size tested: 3048 mm (120 in) span/ 1371 mm (54 in) TribWd MA
  • 9000 Series Fixed Window
    • Model No.: Axis-9000FW-IGXX
    • Class LC – PG30 – Size tested: 1815 x 2425 mm (71.5 x 95.5 in)- Type FW
    • Thermal simulation performed for seven double glazing options.
    • Please refer to the result from report no. 40.00.22480-1
  • 9000 Series Horizontal Sliding Window
    • Model No.: Axis-9000HS-IGXX
    • Class LC – PG25 – Size tested: 3048 x 1828 mm (120 x 72 in) – Type HS
    • Operable sash size tested: 914 x 1828 mm
    • Thermal simulation performed for four double glazing options.

Legend for Coding System and Energy Performance Values:

  • XX’ is the applicable glazing option (7 options currently as shown below)

Glazing Options for 9000 Series Fixed Window:

  • Option 01: LoE 272 on 3mm Clear / Air (15.875mm) / 3mm Clear
  • Option 02: LoE 272 on 3mm Clear / Argon (90%) (15.875mm) / 3mm Clear
  • Option 03: LoE 272 on 3mm Clear / Argon (90%) (15.875mm) / i89 on 3mm
  • Option 04: LoE 366 on 3mm Clear / Argon (90%) (15.875mm) / i89 on 3mm
  • Option 05: LoE 272 on 6mm Clear / Argon (90%) (9.525mm) / 6mm Clear
  • Option 06: LoE 272 on 6mm Clear / Argon (90%) (9.525mm) / i89 on 6mm

Thermal Simulation Results for 9000 Series Fixed Window:

  • IG01: U factor (W/m2-K): 1.77; SHGC: 0.33; VT: 0.56; Air Leakage: 0.2; Energy Rating: 20
  • IG02: U factor (W/m2-K): 1.57; SHGC: 0.33; VT: 0.56; Air Leakage: 0.2; Energy Rating: 24
  • IG03: U factor (W/m2-K): 1.33; SHGC: 0.32; VT: 0.55; Air Leakage: 0.2; Energy Rating: 29
  • IG04: U factor (W/m2-K): 1.30; SHGC: 0.21; VT: 0.50; Air Leakage: 0.2; Energy Rating: 23
  • IG05: U factor (W/m2-K): 1.61; SHGC: 0.32; VT: 0.54; Air Leakage: 0.2; Energy Rating: 23
  • IG06: U factor (W/m2-K): 1.35; SHGC: 0.21; VT: 0.48; Air Leakage: 0.2; Energy Rating: 22
  • IG07: U factor (W/m2-K): 1.38; SHGC: 0.31; VT: 0.53; Air Leakage: 0.2; Energy Rating: 27

Thermal Simulation Results for 9000 Series Horizontal Sliding Window:

  • IG01: U factor (W/m2-K): 1.83; SHGC: 0.31; VT: 0.53; Air Leakage: 0.4; Energy Rating: 17
  • IG02: U factor (W/m2-K): 1.65; SHGC: 0.31; VT: 0.53; Air Leakage: 0.4; Energy Rating: 21
  • IG03: U factor (W/m2-K): 1.42; SHGC: 0.31; VT: 0.52; Air Leakage: 0.4; Energy Rating: 26
  • IG04: U factor (W/m2-K): 1.40; SHGC: 0.20; VT: 0.47; Air Leakage: 0.4; Energy Rating: 20
  • AAMA/WDMA/CSA 101/I.S.2/A440:22
  • CSA A440S1:19
  • CSA A440.2:19
  • Products are certified for Canadian Market only

General Note:

  • Project no.:22480
  • LC Listing Report no.: 40.00.22480-3_Rev.0
  • LC Certificate no.: LC22480-3