Certification Record
LC1231551
SENKO Co., Ltd.
2025-10-28
Gyeonggi-do
Korea, Republic of
SI-200E, SI-200A
29.260.20,19.080
- Single Transmitter
- Model No.: SI-200E
- Ratings:
- Hazardous Location Ratings:
- Class I, Zone 1, AEx db IIC T6 Gb
- Ex db IIC T6 Gb
- Class II, Zone 21, AEx tb IIIC T80°C Db IP66
- Ex tb IIIC T80°C Db IP66
- -40 ºC to +60 ºC
- Electrical Rating:
- DC 24V (nominal, ±10 %), 3.6 W
- Hazardous Location Ratings:
- Model: SI-200A
- Ratings:
- Hazardous Location Ratings:
- Class I, Zone 1, AEx db IIC T4 Gb
- Ex db IIC T4 Gb
- Class I, Zone 0, AEx ia IIC T4 Ga
- Ex ia IIC T4 Ga
- Class I, Div 1, Group A, B, C, and D
- -40 ºC to +60 ºC
- Electrical Rating:
- DC 24V (nominal, ±10 %), 3.6 W, Um = 250 V
- Hazardous Location Ratings:
- CSA C22.2 No. 60079-0:19
- UL 60079-0:2019
- CAN/CSA-C22.2 No. 60079-1:16
- UL 60079-1:2015
- CAN/CSA-C22.2 No. 60079-31:15
- UL 60079-31:2020
- CAN/CSA-C22.2 No. 60079-11:14
- UL 60079-11: Edition 6
- CSA-C22.2 No. 61010-1:12
- UL 61010-1:12 – (June 2023)
- SI-200E
- For details on flameproof joints, the manufacturer shall be contacted.
- WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD – SEE INSTRUCTION
- For IPX6, a splash guard shall be employed and the angle of the sensor in the equipment shall be positioned lower than horizontal.
- SI-200A
- The usable ambient temperature around the gas sensor shall be limited to the operating temperature specified in the manufacturer’s datasheet.
General Note:
- Project no.: 25-1017
- LC Listing Report no.: 11.03.25-1017-1_Rev.0
- LC Certificate no.: LC25-1017-1