Certification Record
LC 1253096
Caron Measurement and Controls Ltd
2026-02-13
Alberta
Canada
CMC-ELM-TMR-00-XX, CMC-ELM-TMR-MD-XX, CMC-ELM-TMR-AC1D, CMC-ELM-MSXP
33.160.01; 35.020
- Eliminator Programmable Controllers (Explosion Proof) Series
- Model Nos.: CMC-ELM-TMR-00-XX, CMC-ELM-TMR-MD-XX,
CMC-ELM-TMR-AC1D, CMC-ELM-MSXP - Ratings:
- With Motor Control Board (CMC-ELM-TMR-AC-1D, CMC-ELM-TMR-MD-XX, CMC-ELM-000-MDXX) – Round Enclosures, (CMC-ELM-TMR-AC-1D includes square enclosure and does not necessarily require -40°C)
- Hazardous Location Ratings:
- Class I, Division 1, Group D T4A; Class I, Zone 1 Ex db IIA, IIB T4A Gb;
- Type 4X
- Ambient Temperature: -40°C ≤ Tamb ≤ 40°C
- Electrical Ratings:
- Voltage: 10-30 VDC, Max Cont. Current: 20A.
- Hazardous Location Ratings:
- With Motor Control Board (CMC-ELM-TMR-AC-1D, CMC-ELM-TMR-MD-XX, CMC-ELM-000-MDXX) – Round Enclosures, (CMC-ELM-TMR-AC-1D includes square enclosure and does not necessarily require -40°C)
- Without Motor Control Board (CMC-ELM-TMR-00-XX, CMC-ELM-MSXP, CMC-ELM-MSXPW)
- Hazardous Location Ratings:
- Class I, Division 1, Group C, D T5; Class I, Zone 1 Ex db IIA, IIB T5 Gb;
- Type 4X
- Ambient Temperature: -40°C ≤ Tamb ≤ 40°C
- Hazardous Location Ratings:
-
- Electrical Ratings:
-
- Voltage: 9-30 VDC, Max Cont. Current: 2A
-
- Electrical Ratings:
- CMC-ELM-MSXPW
- Hazardous Ratings:
- Class I, Division 1, Group C, D T5; Class I, Zone 1 Ex db IIA, IIB T5 Gb;
- Type 4X
- Ambient Temperature: -40°C ≤ Tamb ≤ 40°C
- Electrical Ratings:
- Voltage: 6-30 VDC, Max Cont. Current: 2A
- CSA C22.2 No. 14-18 (R2022)
- UL 508, Edition 18
- CSA C22.2 No. 30:20
- CSA C22.2 No. 60079-0:2019
- CSA-C22.2 No. 60079-1:16 (R2021)
- UL 1203 – Edition 5
- UL60079-0 – Edition 7
- UL 60079-1 – Edition 7
- The approved construction of the labelled product is as described below in this report.
- Certification is voided if the labeled product has been modified or changed by the manufacturer or end user after labeling.
- Certification covers only safety from electric shock and fire/explosion hazards and apply only to the construction elements described in this report.
- LC did not evaluate the suitability of the use of equipment involving toxic or corrosive gases; steam locations defined as hazardous locations by the Canadian Electrical Code or the National Electrical Code.
General Note:
- Project no.: T-22348
- LC Listing Report no.: 11.02.22348-1_Rev.0
- LC Certificate no.: LC22348-1