Certification Record
LC 1250219
Galvanic Applied Sciences Inc.
2026-02-23
Alberta
Canada
Gas Micro Models EVC, EPR and IM-P-T
- Electronic Volume Corrector & data Logger
- Ratings:
- Gas Micro Models EVC, EPR and IM-P-T
- Hazardous Location Ratings:
- Class I, Div. 1, Group B, C and D, T3C
- Ambient Temperature: -40°C < Tamb < +65°C; Encl. Type 3R
- Electrical Ratings:
- 5-9.5Vdc, 30mA;
- Powered by 9Vdc battery packs BA1938 and BA1770; battery receptacle CA2125, or by I. S. Barrier when installed
- Solar Power/Battery Combination: 15.6Vdc (max), 10W (max) by I. S. Barrier when installed
- Hazardous Location Ratings:
- Gas Micro Models EVC, EPR or IM-P-T
- Hazardous Location Ratings:
- Class I, Div. 2, Group B, C and D, T3C
- Ambient Temperature: -40°C < Tamb < +65°C; Encl. Type 3R
- Electrical Ratings:
- 5-9.5Vdc, 30mA;
- Powered by 9Vdc battery packs BA1938 and BA1770; battery receptacle CA2125,
- Solar Power/Battery Combination: 15.6Vdc (max), 10W (max.)
- Hazardous Location Ratings:
- Gas Micro Models EVC, EPR and IM-P-T
Note:
Ambient Temperature:
-40C to +65C for lithium battery
-18C to 55C for alkaline battery
- CSA C22.2 No. 30:20
- CAN/CSA-C22.2 No. 157-92 (R2021
- CSA-C22.2 No. 60079-11:14 (R2018)
- CSA 94.2:20
- UL 1203, Ed. 6
- UL 913, Ed. 8
- UL 60079-11, Ed. 6
- UL 50E, Ed. 2
- CAN/CSA-C22.2 No. 61010-1-12, UPD1:2015, UPD2: 2016, AMD1: 2018
- CSA C22.2 No.61010-2-010:19
- UL 61010-1, 3rd Ed. (2012), AMD1: 2018 -UL 61010-2-010 (4th Ed.)
- P1, P13, P102 and JP2 may all be connected through external barriers at the same time, however JP2 may only be connected through channel 7 individually, or channels 8 and 9 together, not all three simultaneously.
- Batteries must only be changed and/or replaced in an area known to be non-hazardous.
- When I.S. barriers are used, install as per Dwg. “Gas Micro I.S. wiring”
- Equipment to be supplied by a certified Class 2 Power Supply.
General Note:
- Project no.: T-22309
- LC Listing Report no.: 11.03.22309-1_Rev.0
- LC Certificate no.: LC22309-1