LC Clients

Certification Record

LC1231751
Victron Energy B.V.
2026-04-14
JG Almere Haven
Netherlands
Stand-along Inverter 12, 24, 48
29.200
  • Stand-alone Inverter

 

  • Model Nos.:
    • Inverter 12 | 1600 120V VE.Direct NEMA GFCI
    • Inverter 24 | 1600 120V VE.Direct NEMA GFCI
    • Inverter 48 | 1600 120V VE.Direct NEMA GFCI
    • Inverter 12 | 1200 120V VE.Direct NEMA GFCI
    • Inverter 24 | 1200 120V VE.Direct NEMA GFCI
    • Inverter 48 | 1200 120V VE.Direct NEMA GFCI
    • Inverter 12 | 800 120V VE.Direct NEMA GFCI
    • Inverter 24 | 800 120V VE.Direct NEMA GFCI
    • Inverter 48 | 800 120V VE.Direct NEMA GFCI
    • Inverter 12 | 500 120V VE.Direct NEMA GFCI
    • Inverter 24 | 500 120V VE.Direct NEMA GFCI
    • Inverter 48 | 500 120V VE.Direct NEMA GFCI
    • Inverter 12 | 375 120V VE.Direct NEMA GFCI
    • Inverter 24 | 375 120V VE.Direct NEMA GFCI
    • Inverter 48 | 375 120V VE.Direct NEMA GFCI
    • Inverter 12 | 250 120V VE.Direct NEMA GFCI
    • Inverter 24 | 250 120V VE.Direct NEMA GFCI
    • Inverter 48 | 250 120V VE.Direct NEMA GFCI
  • Ratings:
    Inverter VE.Direct 120V 12/250
    24/250
    48/250
    12/375

    24/375

    48/375

    12/500
    24/500
    48/500
    12/800
    24/800
    48/800
    12/1200

    24/1200
    48/1200

     

    12/1600
    24/1600
    48/1600
    Cont. Power at 25°C   250W   375W   500W   800W   1200W   1500W
    Cont. Power at 40°C 200W 300W 438W 650W 1100W 1350W
    Time-limited power (cold start) 300W/15s 450W/25s 500W/1h 900W/1h 1300W/1h 1700W/1h
    Peak power 400W/2s 600W/2s 750W/2s 1200W/15s 1600W/15s 2100W/15s
    Output AC (voltage, current,

    Frequency)

    1.70Aac 2.5Aac 3.35Aac 5.4Aac 8.0Aac 10.9Aac
    120Vac +/-3%

    60Hz +/-0.1%

    Input DC

    voltage range

    current:

    12V battery

    24V battery

    48V battery

    9.2 – 17V

    18.4 – 34.0V

    36.8 – 62V

    23Adc

    12Adc

    6Adc

    35Adc

    18Adc

    9Adc

    50Adc

    25Adc

    13Adc

    76Adc

    38Adc

    19Adc

    120Adc

    60Adc

    30Adc

    160Adc

    80Adc

    40Adc

    Operating temperature range -40 to +60°C (fan-assisted cooling)
    Power derating 1.25% per °C above 40°C
  • UL 458 (Ed.6)
  • Inverter intended to be used indoors, built-in in a cabinet, non-condensing humidity of max 95%, in ambient temperature of -40 to +60°C.
  • This is a Safety class I product (supplied with a protective grounding terminal). The chassis must be grounded.
  • The AC output is isolated from the DC input and the chassis unless the unit is equipped with a Ground Fault Circuit Interruper (GFCI). Local regulations may require a true neutral. In this case, one of the AC output wires must be connected to the chassis, and the chassis must be connected to a reliable ground. The true neutral is needed to ensure the current operation of an earth leakage circuit breaker.

General Note:

  • Project no.: 20760B
  • LC Listing Report no.: 10.00.20760-1_Rev.B
  • LC Certificate no.: LC20760-1
Go to Top