Certification Record
LC1252748
Impossible Sensing Energy Inc.
2026-05-20
Alberta
Canada
Flow-MKV
29.260.20, 21.180 and 19.080
- Multiphase Meter
- Model: Flow-MKV
- Ratings:
- Hazardous Location Ratings:
Class I, Division 2, Group D; T3
Ambient temperature: -40°C to +40°C
Process temperature: -40°C to +75°C
Enclosure Type 4 - Electric ratings: 24 Vdc, 1.7 A max
- Hazardous Location Ratings:
- CSA C22.2 No. 94.2:20 (R2025): Enclosures for electrical equipment, environmental considerations (Tri-national standard with NMX-J-235/2-ANCE-2020 and UL 50E)
- C22.2 No. 213-17 (R2022) – Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations (bi-national with UL 121201)
- CSA C22.2 No. 61010-1:2012/ UL 61010-1 3rd Edition: Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, Part 1: General Requirements
- The equipment must be powered from a suitably certified Class 2 power supply.
- The end user is to ensure appropriate earthing upon installation.
- The final installation of the device shall be in full compliance with the applicable wiring method requirements of the Canadian Electrical Code (CEC) for Class I, Division 2 installations in Canada and the National Electrical Code (NEC) for installations in the United States and shall be subject to approval by the applicable Authorities Having Jurisdiction (AHJ).
- End users shall follow specific installation and operating instructions supplied by the manufacturer to prevent exceeding the heat dissipating limits for the desired temperature code for an operating temperature ambient.
- No changes to or modifications are permitted without additional assessment.
General Notes:
- LC Project no.: 25-5721
- LC Certificate no.: LC25-5721-1
- LC Listing Report no.: 11.03.25-5721-1_Rev0