LC Clients

Certification Record

LC1250779
Avari Wireless Inc.
2026-06-08
British Columbia
Canada
VL-DU-A-BC-D & VL-CLK-BC-D
33.060.20 , 33.060.30
  • Optical Distribution Unit
  • Model Nos.:
    • VL-DU-A-BC-D
    • VL-CLK-BC-D

The following denotes the specific model nomenclature as indicated in the Product Covered.
VL-DU-A-BC-D & VL-CLK-BC-D where:
A: Port Number
8 = 8 Ports (1 Slave Ports and 7 Master Ports)
14 = 14 Ports (1 Slave Ports and 13 Master Ports)

B: Environmental Protection
0 = non-NEMA
1 = NEMA4

C: Unit Input Power
D = 48Vdc powered

D: Enclosure Color
R = Red
B = Beige

  • Ratings: 48Vdc input voltage, 2.1/1.1 A input current, power consumption ≤ 100W/50W
  Model VL-DU-14 VL-DU-8

VL-CLK

Primary Power Source Input Voltage, Vdc 48 48
Operating Voltage for compatibility, Vdc 40.8 – 57.6 40.8 – 57.6
Input Frequency, Hz N/A N/A
Input Current, A 2.1 (100 W) 1.1 (50 W)
Supervised # Yes Yes
Power Limited # No No

#- Requires separately UL 2524 approved power supply.

Trouble Contacts

(6 total)

Dry Contact Voltage, V dc 30
Dry Contact Current, A resistive 2
Restricted to 30 m (98.5 ft) long No
Optical Fiber Network Supervised Yes
Wavelength, nm 1270 and 1330
Max optical Loss 10km: 13dBo

40km: 19dBo

80km: 27dBo

  • ANSI / CAN / UL 2524:2024, Edition 3

These products are to be installed in accordance with the following.
A. International Fire Code (IFC)
B. NFPA 1 Fire Code
C. NFPA 70 National Electrical Code
D. NFPA 72 National Fire Alarm and Signaling Code
E. NFPA 1221 Installation, Maintenance, and Use of Emergency Services Communications Systems
F. NFPA 1225 Emergency Services Communications

Openings are provided on the unit so that the field wiring may be run in conduit if required by the local authority having jurisdiction.
All field wiring connections are intended to be made at the installation wiring terminals provided as part of the unit.

The field wiring circuits are rated as follows: 48 Vdc Input Power

Installation Instructions – The installation instructions indicated below shall be shipped with the indicated product.

  Installation Instructions
Models Doc. Part No. Rev Level / Date
All VL-DU, VL-CLK AW-MAN-01-R16.3 December 2025

 

General Notes:

  • LC Project no.:26-5832
  • LC Certificate no.: LC26-5832-1
  • LC Listing Report no.: 10.00.26-5832-1_Rev0
Go to Top