Certification Record
LC1254184
Haider Drive Tech Co. Ltd.
2026-06-19
Jiangsu
China
HGL465-3550-HV-10mm (motor) HGL465-3535-HV-10mm (motor) HGL465-3520-HV-10mm (motor) BLB14A (brake)
91.140.90
- Permanent magnet elevator traction machine
- Model No.:
- HGL465-3550-HV-10mm (motor)
- HGL465-3535-HV-10mm (motor)
- HGL465-3520-HV-10mm (motor)
- BLB14A (brake)
- Ratings:
- HGL465-3550-HV-10mm: 330Vac, 58A, 34.3Hp, 159r/min, S5 40% duty cycle/VT
- HGL465-3535-HV-10mm: 330Vac, 41.6A, 24.0Hp, 111r/min, S5 40% duty cycle/VT
- HGL465-3520-HV-10mm: 330Vac, 26A, 13.8Hp, 64r/min, S5 40% duty cycle/VT
- BLB14A: 110Vdc, 2.2A, 242W, Int duty, on 8s, off 12s
- CSA B44.1:25 / ASME A17.5-2025
- UL 1004-1 Ed. 2
- CSA C22.2 No. 100-14
- CSA C22.2 No. 14-18 (R2022)
- For installations at altitudes below 1000m, or above 1000m where special tractor designs are required, users must provide written specifications during order placement.
- The air temperature in the server room should be maintained between +5°C and +40°C.
- The relative humidity of the air at the operating site shall not exceed 50% at the highest temperature of +40°C. Higher relative humidity may occur at lower temperatures. The monthly average minimum temperature during the wettest month shall not exceed +25°C, and the monthly average maximum relative humidity during that month shall not exceed 90%. If condensation is likely to form on the equipment, appropriate measures shall be taken.
- The ambient air should not contain corrosive or flammable gases;
- The voltage fluctuation and deviation from rated value of the power grid supply voltage shall not exceed ±7%.
General Notes:
- LC Project no.: 26-5817
- LC Certificate no.: LC26-5817-1
- LC Listing Report no.: 10.00.26-5817-1_Rev 0