LC Clients

Certification Record

LC1254676
Forge XP Inc.
2026-08-28
Ontario
Canada
FX-080605 , FX-110605 , FX-100806 , FX-180705 , FX-180708 , FX-121206 , FX-121208 , FX-181208 , FX-181808 , FX-241808 , FX-241812 , FX-242408 , FX-242412 , FX-302408 , FX-302412
21.180 ; 29.260.20
  • Flameproof Cast Aluminum and/or Stainless-Steel Enclosures
  • Models: FX-080605, FX-110605, FX-100806, FX-180705, FX-180708, FX-121206, FX-121208, FX-181208, FX-181808, FX-241808, FX-241812, FX-242408, FX-242412, FX-302408, and FX-302412
  • Ratings:
    • Hazardous Location Ratings:
      • Class I, Division 1, Groups B, C, D T4 and
      • Class II, Division 1, Groups F, G T135°C
      • Class I, Zone 1 AEx db IIB, IIC T4 and
      • Ex db IIB, IIC T4
      • Class II, Zone 21 AEx tb IIIB, IIIC T135°C and
      • Ex tb IIIB, IIIC T135°C. Encl. Type 4X
      • Ta: -40°C to +40°C.
    • Electric ratings:
      • Minimum Voltage and Max Voltage: 24V Dc to 600V
      • Minimum and Maximum Amperage: 0A and 250A.
  • UL 50E Ed. 3rd/CSA C22.2 No. 94.2 -20
  • UL 1203 (Ed. 5)
  • CSA-C22.2 No. 30:20
  • CSA-C22.2 No. 60079-0:19
  • UL 60079-0:2019
  • CAN/CSA-C22.2 No. 60079-1:16
  • UL 60079-1:2015
  • CAN/CSA-C22.2 No. 60079-31:15 (IEC 60079-31:2013, MOD)
  • UL 60079-31:2020
  1. Wiring method must be defined in the Canadian Electrical Code or National Electrical Code.
  2. Not evaluated for use with flammable fluids.
  3. Entries not used must be provided with certified plugs.

General Note:

  • LC Project no.: 25-1092
  • LC Certificate no.: LC26CA25-1092-1
  • LC Listing Report no.: 11.03.25-1092-1_Rev 0
Go to Top