LC Clients

Certification Record

LC1231751
Victron Energy B.V.
2026-09-14
Almere
Netherlands
MultiPlus-II 12/3000/120-50 120V , MultiPlus-II 12/3000/120-50 2x120V , MultiPlus-II 24/3000/70-50 120V , MultiPlus-II 24/3000/70-50 2x120V , MultiPlus-II 48/3000/35-50 120V , MultiPlus-II 48/5000/70-95 120V
29.200
  • Battery Inverter/Charger
  • Model no:
    • MultiPlus-II 12/3000/120-50 120V,
    • MultiPlus-II 12/3000/120-50 2x120V
    • MultiPlus-II 24/3000/70-50 120V,
    • MultiPlus-II 24/3000/70-50 2x120V
    • MultiPlus-II 48/3000/35-50 120V,
    • MultiPlus-II 48/5000/70-95 120V
  • Ratings:

MultiPlus-II 12/3000/120-50 120V

Max. bypass current (A AC) 50
INVERTER
Input voltage range (V DC) 9,5 – 17
Input current (A DC) 250
Output Output voltage: 120 VAC ± 2%

Frequency: 50/60 Hz ± 0,1%

Cont. output power at 25°C (VA) (nonlinear load, crest factor 3:1) 3000
Cont. output power at 25°C (W) 2400
Output current (A AC) 20

CHARGER

AC Input Single phase: 90-140 VAC 45 – 65 Hz
Charge voltage nominal (V DC) 12
Charge current house battery (A) (25°C) 120

MultiPlus-II 12/3000/120-50 2x120V

Max. bypass current (A AC) 50
INVERTER
Input voltage range (V DC) 9,5 – 17
Input current (A DC) 250
Output Output voltage: 120 VAC ± 2%

Frequency: 50/60 Hz ± 0,1%

Cont. output power at 25°C (VA) (nonlinear load, crest factor 3:1) 3000
Cont. output power at 25°C (W) 2400
Output current (A AC) 20

CHARGER

AC Input Split phase: 180-280 VAC 45 – 65 Hz

Single phase: 90-140 VAC 45 – 65 Hz

Charge voltage nominal (V DC) 12
Charge current house battery (A) (25°C) 120

MultiPlus-II 24/3000/70-50 120V

Max. bypass current (A AC) 50
INVERTER
Input voltage range (V DC) 19 – 33
Input current (A DC) 125
Output Output voltage: 120 VAC ± 2%

Frequency: 50/60 Hz ± 0,1%

Cont. output power at 25°C (VA) (nonlinear load, crest factor 3:1) 3000
Cont. output power at 25°C (W) 2400
Output current (A AC) 20

CHARGER

AC Input Single phase: 90-140 VAC 45 – 65 Hz
Charge voltage nominal (V DC) 24
Charge current house battery (A) (25°C) 70

MultiPlus-II 24/3000/70-50 2x120V

Max. bypass current (A AC) 50
INVERTER
Input voltage range (V DC) 19 – 33
Input current (A DC) 125
Output Output voltage: 120 VAC ± 2%

Frequency: 50/60 Hz ± 0,1%

Cont. output power at 25°C (VA) (nonlinear load, crest factor 3:1) 3000
Cont. output power at 25°C (W) 2400
Output current (A AC) 20

CHARGER

AC Input Split phase: 180-280 VAC 45 – 65 Hz

Single phase: 90-140 VAC 45 – 65 Hz

Charge voltage nominal (V DC) 24
Charge current house battery (A) (25°C) 70

MultiPlus-II 48/3000/35-50 120V

Max. bypass current (A AC) 50
INVERTER
Input voltage range (V DC) 38 – 66
Input current (A DC) 75
Output Output voltage: 120 VAC ± 2%

Frequency: 50/60 Hz ± 0,1%

Cont. output power at 25°C (VA) (nonlinear load, crest factor 3:1) 3000
Cont. output power at 25°C (W) 2400
Output current (A AC) 20

CHARGER

AC Input Single phase: 90-140 VAC 45 – 65 Hz
Charge voltage nominal (V DC) 48
Charge current house battery (A) (25°C) 35

MultiPlus-II 48/5000/70-95 120V

Max. bypass current (A AC) 95
INVERTER
Input voltage range (V DC) 38 – 66
Input current (A DC) 110
Output Output voltage: 120 VAC ± 2%

Frequency: 50/60 Hz ± 0,1%

Cont. output power at 25°C (VA) (nonlinear load, crest factor 3:1) 5000
Cont. output power at 25°C (W) 4000
Output current (A AC) 33

CHARGER

AC Input Single phase: 90-140 VAC 45 – 65 Hz
Charge voltage nominal (V DC) 48
Charge current house battery (A) (25°C) 70

 

  • UL 458, 6th Edition, rev. January 11, 2021: Standard for Power Converters/Inverters and Power Converter/Inverter Systems for Land Vehicles and Marine Crafts
  • None

General Note:

  • LC Project no.: 20469F
  • LC Certificate no.: LC20469-3
  • LC Listing Report no.: 10.00.20469-3_Rev F
Go to Top