1026136
Sonoco Flexible Packaging
2012-05-14
Ontario
Canada
7831
29.260.20

Printing press, PCMC Vision II

Rated: 480V,170A,3ph,60Hz,SCCR=5KA@480V

Class I Div 2, Group D, T4

CSA-C22.2 No. 14-10

CAN/CSA-C22.2 No. 157-92 (R2006)

CSA C22.1 Section 18

All exhaust and make-up air systems to be adjusted, and capacities and velocities verified by a competent
person to provide sufficient negative pressure within enclosures to minimize fugitive emissions and to
ensure concentration of vapour-air mixtures are less than 25% of LEL and to ensure that exit velocities are
sufficient to prevent downdraft. All above-roof exhaust stacks must meet applicable regulations and be located at least 25 feet from any air intake.

Floor level exhaust is required at ink dispensing/pumping area and must be sufficient to ensure the flammable vapour concentrations do not exceed 25% of LEL.

LEL detectors to be located at all 4 corners of the wet section of the press and implemented as per the CEC.