Certification Record
Ø Outdoor Decorative Gas Appliance
Ø Model: Commercial Grade All Weather Electronic Ignition System (AWEIS), standard and high capacity. See Table 1 for list of all models.
Ø Ratings:
Ø CSR6-36 – Minimum 25,000/Maximum 250,000 BTU/hr
Ø CSLO6-36 – Minimum 45,000/Maximum 270,000 BTU/hr
Ø CSRT48-120 – Minimum 50,000/Maximum 130,000 BTU/hr
Ø CSRH624-696 – Minimum 52,000/Maximum 200,000 BTU/hr
Ø CHR30-48 – Minimum 175,000/Maximum 350,000 BTU/hr
Ø CHLO30-48 – Minimum 195,000/Maximum 370,000 BTU/hr
Ø CHRT120-180 – Minimum 130,000/Maximum 205,000 BTU/hr
Ø CHRH696-6120 – Minimum 200,000/Maximum 260,000 BTU/hr
Ø Electrical (all models): 24VAC / 1.5A / 60HZ or optional 12 Vac system
Model Number |
Description |
Nominal Gas Load (BTU/hr) |
|
Commercial Grade AWEIS Standard Capacity Electronic Ignition System Recessed Pilot Burner Configuration with Heat Shield Flat Burner Pan or Bowl Style Burner Pan and Round/Square Burner |
|
||
CSR6-36 |
CSR6 |
Commercial Grade AWEIS SC/Recessed with 6” Round/Square Burner |
25,000 |
CSR12 |
Commercial Grade AWEIS SC/Recessed with 12” Round/Square Burner |
45,000 |
|
CSR18 |
Commercial Grade AWEIS SC/Recessed with 18” Round/Square Burner |
75,000 |
|
CSR24 |
Commercial Grade AWEIS SC/Recessed with 24” Round/Square Burner |
125,000 |
|
CSR30 |
Commercial Grade AWEIS SC/Recessed with 30” Round/Square Burner |
150,000 |
|
CSR30HC |
Commercial Grade AWEIS SC/Recessed with 30” High Capacity Round/Square Burner |
175,000 |
|
CSR36HC |
Commercial Grade AWEIS SC/Recessed with 36” High Capacity Round/Square Burner |
250,000 |
|
Commercial Grade AWEIS Standard Capacity Electronic Ignition System Lateral Offset Pilot Burner Configuration with Heat Shield Flat Burner Pan or Bowl Style Burner Pan and Round/Square Burner |
|
||
CSLO6-36 |
CSLO6 |
Commercial Grade AWEIS SC/Lateral Offset with 6” Round/Square Burner |
45,000 |
CSLO12 |
Commercial Grade AWEIS SC/Lateral Offset with 12” Round/Square Burner |
65,000 |
|
CSLO18 |
Commercial Grade AWEIS SC/Lateral Offset with 18” Round/Square Burner |
95,000 |
|
CSLO24 |
Commercial Grade AWEIS SC/Lateral Offset with 24” Round/Square Burner |
145,000 |
|
CSLO30 |
Commercial Grade AWEIS SC/Lateral Offset with 30” Round/Square Burner |
170,000 |
|
CSLO30HC |
Commercial Grade AWEIS SC/Lateral Offset with 30” High Capacity Round/Square Burner |
195,000 |
|
CSLO36HC |
Commercial Grade AWEIS SC/Lateral Offset with 36” High Capacity Round/Square Burner |
270,000 |
Model Number |
Description |
Nominal Gas Load (BTU/hr) |
||
Commercial Grade AWEIS Standard Capacity Electronic Ignition System Recessed Pilot Burner Configuration with Heat Shield Flat Burner Pan or Trough Style Burner Pan and T- Burner |
|
|||
CSRT48-120 |
CSRT48 |
Commercial Grade AWEIS SC/Recessed with 48” T-Burner and Burner Pan |
50,000 |
|
CSRT60 |
Commercial Grade AWEIS SC/Recessed with 60” T-Burner and Burner Pan |
62,000 |
||
CSRT72 |
Commercial Grade AWEIS SC/Recessed with 72” T-Burner and Burner Pan |
75,000 |
||
CSRT84 |
Commercial Grade AWEIS SC/Recessed with 84” T-Burner and Burner Pan |
87,000 |
||
CSRT96 |
Commercial Grade AWEIS SC/Recessed with 96” T-Burner and Burner Pan |
100,000 |
||
CSRT108 |
Commercial Grade AWEIS SC/Recessed with 108” T-Burner and Burner Pan |
115,000 |
||
CSRT120 |
Commercial Grade AWEIS SC/Recessed with 120” T-Burner and Burner Pan |
130,000 |
||
Commercial Grade AWEIS Standard Capacity Electronic Ignition System Recessed Pilot Burner Configuration with Heat Shield Flat Burner Pan or Trough Style Burner Pan and H – Burner |
|
|||
CSRH624-696 |
CSRH624 |
Commercial Grade AWEIS SC/Recessed with 24” H-Burner and Burner Pan |
52,000 |
|
CSRH636 |
Commercial Grade AWEIS SC/Recessed with 36” H-Burner and Burner Pan |
76,000 |
||
CSRH648 |
Commercial Grade AWEIS SC/Recessed with 48” H-Burner and Burner Pan |
100,000 |
||
CSRH660 |
Commercial Grade AWEIS SC/Recessed with 60” H-Burner and Burner Pan |
124,000 |
||
CSRH672 |
Commercial Grade AWEIS SC/Recessed with 72” H-Burner and Burner Pan |
150,000 |
||
CSRH684 |
Commercial Grade AWEIS SC/Recessed with 84” H-Burner and Burner Pan |
174,000 |
||
CSRH696 |
Commercial Grade AWEIS SC/Recessed with 96” H-Burner and Burner Pan |
200,000 |
||
ANSI Z21.97: 2014 / CSA 2.41: 2014 – Outdoor Decorative Gas Appliances;
CSA C22.2 No. 3 M1998 (R2014) – Electrical Features for Fuel Burning Equipment.
Intended to be used outdoors only with heat shield or burner pan and approved media installed.
Approved media is to be landscape lava rock filler material topped with large chunk lava rocks, fire-glass, or steel log set.
All models are acceptable for use with natural gas or propane, the “LP” designation after the model number indicates that model is for use with propane only. Without the “LP” model number designation, the model is for use with natural gas only.
All 12Vac rated models shall include “-12Vac” added to the model name. Marking labels’ electrical ratings shall be reflective of the 12Vac rating for all “-12Vac” models.
Acceptable burner pan types include flat burner pan, bowl style burner pan, or round/square burner pan. Acceptable burner types include round/square burners, T-burners, and H-burners.
Pilot configurations include a lateral offset and a recessed configuration.