LC Clients

Certification Record

LC 1225106
Fire by Design
2016-09-16
Nevada
United States
Commercial Grade AWEIS
29.260.10

Ø  Outdoor Decorative Gas Appliance

Ø    Model:  Commercial Grade All Weather Electronic Ignition System (AWEIS), standard and high capacity. See Table 1 for list of all models.

Ø       Ratings:     

Ø  CSR6-36 – Minimum 25,000/Maximum 250,000 BTU/hr

Ø  CSLO6-36 – Minimum 45,000/Maximum 270,000 BTU/hr

Ø  CSRT48-120 – Minimum 50,000/Maximum 130,000 BTU/hr

Ø  CSRH624-696 – Minimum 52,000/Maximum 200,000 BTU/hr

Ø  CHR30-48 – Minimum 175,000/Maximum 350,000 BTU/hr

Ø  CHLO30-48 – Minimum 195,000/Maximum 370,000 BTU/hr

Ø  CHRT120-180 – Minimum 130,000/Maximum 205,000 BTU/hr

Ø  CHRH696-6120 – Minimum 200,000/Maximum 260,000 BTU/hr

 

Ø  Electrical (all models): 24VAC / 1.5A / 60HZ or optional 12 Vac system

Model Number

Description

Nominal Gas Load (BTU/hr)

Commercial Grade AWEIS High Capacity Electronic Ignition System

Recessed Pilot Burner Configuration with Heat Shield

Flat Burner Pan or Drop-In Style Burner Pan and Round/Square Burner

 

CHR30-48

CHR30HC

Commercial Grade AWEIS HC/Recessed with 30” High Capacity Round/Square Burner

175,000

CHR36HC

Commercial Grade AWEIS HC/Recessed with 36” High Capacity Round/Square Burner

250,000

CHR48HC

Commercial Grade AWEIS HC/Recessed with 48” High Capacity Round/Square Burner

350,000

Commercial Grade AWEIS High Capacity Electronic Ignition System

Lateral Offset Pilot Burner Configuration with Heat Shield

Flat Burner Pan or Bowl Style Burner Pan and Round/Square Burner

 

CHLO30-48

CHLO30HC

Commercial Grade AWEIS HC/Lateral Offset with 30” High Capacity Round/Square Burner

195,000

CHLO36HC

Commercial Grade AWEIS HC/Lateral Offset with 36” High Capacity Round/Square Burner

270,000

CHLO48HC

Commercial Grade AWEIS HC/Lateral Offset with 48” High Capacity Round/Square Burner

370,000

         

 

Model Number

Description

Nominal Gas Load (BTU/hr)

Commercial Grade AWEIS High Capacity Electronic Ignition System

Recessed Pilot Burner Configuration with Heat Shield

Flat Burner Pan or Trough Style Burner Pan and T- Burner

 

CHRT120-180

CHRT120

Commercial Grade AWEIS HC/Recessed with 120” T-Burner and Burner Pan

130,000

CHRT132

Commercial Grade AWEIS HC/Recessed with 132” T-Burner and Burner Pan

145,000

CHRT144

Commercial Grade AWEIS HC/Recessed with 144” T-Burner and Burner Pan

160,000

CHRT156

Commercial Grade AWEIS HC/Recessed with 156” T-Burner and Burner Pan

175,000

CHRT168

Commercial Grade AWEIS HC/Recessed with 168” T-Burner and Burner Pan

190,000

CHRT180

Commercial Grade AWEIS HC/Recessed with 180” T-Burner and Burner Pan

205,000

Commercial Grade AWEIS High Capacity Electronic Ignition System

Recessed Pilot Burner Configuration with Heat Shield

Flat Burner Pan or Trough Style Burner Pan and H – Burner

 

CHRH696-6120

CHRH696

Commercial Grade AWEIS HC/Recessed with 6” x 96” H-Burner and Burner Pan

200,000

CHRH6108

Commercial Grade AWEIS HC/Recessed with 6” x 108” H-Burner and Burner Pan

230,000

CHRH6120

Commercial Grade AWEIS HC/Recessed with 6” x 120” H-Burner and Burner Pan

260,000

 

 

ANSI Z21.97: 2014 / CSA 2.41: 2014 – Outdoor Decorative Gas Appliances;
CSA C22.2 No. 3 M1998 (R2014) – Electrical Features for Fuel Burning Equipment.

Intended to be used outdoors only with heat shield or burner pan and approved media installed.
Approved media is to be landscape lava rock filler material topped with large chunk lava rocks, fire-glass, or steel log set.
All models are acceptable for use with natural gas or propane, the “LP” designation after the model number indicates that model is for use with propane only. Without the “LP” model number designation, the model is for use with natural gas only.
All 12Vac rated models shall include “-12Vac” added to the model name. Marking labels’ electrical ratings shall be reflective of the 12Vac rating for all “-12Vac” models.
Acceptable burner pan types include flat burner pan, bowl style burner pan, or round/square burner pan. Acceptable burner types include round/square burners, T-burners, and H-burners.
Pilot configurations include a lateral offset and a recessed configuration.

Go to Top