Certification Record
LC1225584
IRDI System Inc.
2017-05-05
British Columbia
Canada
Nozzle Receiver - Model I, Options 200075, 200076, 2000365
29.260.20
- Nozzle Receiver
- Model No: Nozzle Receiver Model I, Options 200075, 200076 and 200365
- Ratings: Ui: 8.0 V, Ii: 200 mA, Pi: 0.5 W, Ci: 6.6 uF
- – 40°C ≤ Ta ≤ 85°C
- Ex ib IIC T4 Gb
- Class I Zone 1 AEx ib IIC T4 Gb
- CSA-E60079-11-02 (R2011)
- UL 60079-11 (Ed.5)
- “X” condition:
- The nozzle receiver Model I shall be installed and used in such a way that electrostatic charges are avoided.
- If the nozzle receiver modeI is housed within a metallic enclosure, the enclosure material shall not contain by mass, more than 7% magnesium and titanium.