LC Clients

Certification Record

LC 1230727
Winterwarm B.V.
2018-04-10
Winterswijk
Netherlands
Gas Unit Heaters
  • Gas Unit Heaters
  • Model Nos.: HR50; HC30; HR75; HC50; HR115; HC75; HR150; HC100; HR190; HC125; HR230; HC150
  • Ratings:
    Name Rating max (BTU) Rating min (BTU) Efficiency (Max rating) Efficiency (Min rating) Electric rating (Amp) Rpm Manifold (inwc)
    115 Vac 230 Vac Max Min Max Min
    HR50 NG 47.000 15.000 86.20 % 95.26 % 2.8 1.15 4260 1620 -1,18 -0.14
    LP 47.000 15.000 87.83 % 95.60 % 2.8 1.15 4320 1680 -0.78 -0.08
    HC30 NG 30.000 15.000 91.16 % 95.26 % 2.8 1.15 2880 1620 -0.56 -0.14
    LP 30.000 15.000 92.68 % 95.60 % 2.8 1.15 2880 1680 -0.29 -0.08
    HR75 NG 76.000 23.000 86.85 % 97.16 % 2.8 1.15 4740 1680 -1.6 -0.19
    LP 76.000 23.000 88.48 % 96.94 % 2.8 1.15 4860 1800 -1.28 -0.14
    HC50 NG 49.000 23.000 92.81 % 97.16 % 2.8 1.15 3300 1680 -0.8 -0.19
    LP 49.000 23.000 92.81 % 96.94 % 2.8 1.15 3300 1800 -0.58 -0.14
    HR115 NG 114.000 34.000 87.35 % 96.04 % 2.9 1.21 5040 1860 -0.92 -0.09
    LP 114.000 34.000 89.33 % 96.08 % 2.9 2.21 5340 1980 -2.05 -0.21
    HC75 NG 74.000 34.000 91.45 % 96.04 % 2.9 1.21 3540 1860 -0.44 -0.09
    LP 74.000 34.000 92.81 % 96.08 % 2.9 1.21 3720 1980 -0.91 -0.21
    HR150 NG 151.000 45.000 87.13 % 95.76 % 4.9 2.25 6120 2160 -1.34 -0.13
    LP 151.000 45.000 89.09 % 96.23 % 4.9 2.25 6060 2160 -2.19 -0.22
    HC100 NG 98.000 45.000 91.04 % 95.76 % 4.9 2.25 4080 2160 -0.53 -0.13
    LP 98.000 45.000 92.06 % 96.23 % 4.9 2.25 4200 2160 -1.01 -0.22
    HR190 NG 189.000 57.000 87.65 % 96.69 % 7.0 3.30 6240 2280 -3.9 -0.42
    LP 189.000 57.000 89.51 % 96.74 % 7.0 3.30 6360 2400 -5.02 -0.59
    HC125 NG 123.000 57.000 91.61 % 96.69 % 7.0 3.30 4320 2280 -1.75 -0.42
    LP 123.000 57.000 92.59 % 96.74 % 7.0 3.30 4380 2400 -2.24 -0.59
    HR230 NG 227.000 68.000 87.00 % 95.46 % 7.1 3.38 7400 2500 -2.15 -0.25
    LP 227.000 68.000 89.04 % 96.93 % 7.1 3.38 7200 2450 -2.72 -0.28
    HC150 NG 148.000 68.000 90.95 % 95.46 % 7.1 3.38 5000 2500 -1.03 -0.25
    LP 148.000 68.000 92.09 % 96.93 % 7.1 3.38 5000 2450 -1.3 -0.28
  • ANSI Z83.8 – 2016 / CSA 2.6 – 2016
  • CSA 2.17 – 2017
  • CSA P.11 – 2007 (R. 2013)
  • Suitable for use with Natural Gas or Propane, for indoor use only.
  • Not to be used with solid fuel.
  • The flue gas system must be installed as per the installation manual with usage of tested terminals provided by the manufacturer.