LC Clients

Certification Record

LC1229603
Solarmass Energy Group Ltd.
2018-05-11
British Columbia
Canada
ergosun 15
27.160
  • Photovoltaic Roof Tile
  • Model: ergosun 15
  • Ratings:
    Electrical: ➢ Open Circuit Voltage (Voc): 12 V
    ➢ Short Circuit Current (Isc): 1.20 A
    ➢ Voltage at Maximum Power (Vmp): 10 V
    ➢ Current at Maximum Power (Imp): 1.45 A
    ➢ Maximum Power (Pw): 14.5 W
    ➢ Maximum System Voltage: 600V
    ➢ Nominal Operating Cell Temperature (NOCT): 25°C to 55°C
    ➢ Operating Temperature Range: -40°C to 85°C

Roof Covering Material Fire Class Rating:  ➢ Class A

               Note: Electrical ratings measured in standard test conditions (STC) of 1000 W/m², AM 1.5 spectrum, and 25°C.

  • CAN/CSA-C22.2 NO. 61730-1:11 (R2016) Photovoltaic (PV) module safety qualification – Part 1: Requirements for construction
  • CAN/CSA-C22.2 NO. 61730-2:11 (R2016) Photovoltaic (PV) module safety qualification – Part 2: Requirements for testing
  • UL 1703 (Ed. No.3) Standard for Flat-Plate Photovoltaic Modules and Panels
  • UL 790 (Ed. No.8) Standard for Standard Test Methods for Fire Tests of Roof Coverings
  • Maximum system voltage of 600 V

General Note:

  • Project no. 16963
  • LC Listing Report no. 16963-1S_Rev0
  • LC Certificate no. 16963-1S