LC1230691
A.B. Controls and Technology Inc.
2019-09-23
Texas
United States
IOM SX-OP
29.260.20
  • Products:
    – Type SX Enclosure
    – Model No: IOM SX-OP
  • Ratings:
    Type SX enclosure evaluated and conforms to below ratings for hazardous location with fiber optics components installed inside the enclosure which also complies to the following ratings:
Ratings for Type SX Enclosure
Ex eb op is IIC T5 Gb Class I, Zone 1, AEx  eb op is IIC T5 Gb
Ex ib op is IIC T5 Gb Class I, Zone 1, AEx ib op is IIC T5 Gb
Ex ia op is IIC T5 Ga Class I, Zone 1, AEx ia op is IIC T5 Ga
Ex op is IIC T5 Ga Class I, Zone 1, AEx op is IIC T5 Ga
Ex eb op pr IIC T5 Gb Class I, Zone 1, AEx eb op pr IIC T5 Gb
Ex ib op pr IIC T5 Gb Class I, Zone 1, AEx ib op pr IIC T5 Gb
Ex ia op pr IIC T5 Gb Class I, Zone 1, AEx ia op pr IIC T5 Gb
Ex op pr IIC T5 Gb Class I, Zone 1, AEx op pr IIC T5 Gb
Class I Division 2 Group A, B, C, D
-50˚C≤Ta≤55 ˚C; IP66
  • CAN/CSA-C22.2 No. 60079-0:15 / UL-60079-0 (Ed. 6)
  • CAN/CSA-C22.2 No. 60079-7:16 / UL-60079-7 (Ed. 5)
  • CAN/CSA-C22.2 No. 60079-11:14 / UL-60079-11 (Ed. 6)
  • CAN/CSA-C22.2 No. 60079-28:16 / UL-60079-28 (Ed. 2)
  • C22.2 NO. 213-17 / UL121201 Ed. 9
  • UL 508A (Ed. 3) and C22.2 No. 286-17
  • The Type SX range of junction boxes shall be installed with components which are approved for the application and the suitable hazardous environment.
  • The SX range of junction boxes are fitted with an arrangement of suitably certified terminals. Before the junction box is installed, its total power for particular application will be calculated in accordance with EN 60079-7, Annex E, E.2 and will not exceed the values given in the table below:
SX Ref EPL Max. Power Dissipation

Calculated for T5 at maximum Ta of 55˚C
(W)

SX0 Ga, Gb 19
SX1 Ga, Gb 29
SX2 Ga, Gb 36
SX3 Ga, Gb 42
SX4 Ga, Gb 44
SX5 Ga, Gb 50
SX6 Ga, Gb 57
SX7 Ga, Gb 68
SX8 Ga, Gb 119
SX225 Ga, Gb 359
SX45 Ga, Gb 8
SX64 Ga,Gb 10
SX66 Ga,Gb 114
Optical Power
op pr’ applications op is’ applications
When ‘op pr’ is used, the splice case is limited to 100mW and a -40ºC to 60ºC ambient temperature. When ‘op is’ is used for T5 class to a maximum
irradiance of 5 mW/mm2 (surface area not exceeding 400 mm2) and Signal power is limited to 15 mW@T5.
  • Project No. LV-14757
  • Report No. 14757-1S_Rev0