LC Clients

Certification Record

LC1230773
Eco Heating Systems Groningen B.V.
2018-11-08
Groningen
Netherlands
CB-299-HW, CB-299-HW 8+4, CB-399-HW, CB-499-HW and CB-500-HW
97.100.20, 27.060.01
  • Instantaneous or Circulating Tank Water Heater
  • Model Nos.: CB-299-HW, CB-299-HW 8+4, CB-399-HW, CB-499-HW and CB-500-HW
  • Ratings: See below
    Model (Heat Exchanger and Boiler Type) 7+3 10+6 12+6
    CB-299-HW CB-399-HW CB-499-HW
    MIN MAX MIN MAX MIN MAX
    NG MBTU/HR 60 295 80 396 98 474
    LP MBTU/HR 60 294 80 397 98 473
    Fan Speed (RPM) 1600 6450 1800 6700 (NG)

    6700 (LP)

    2000 7650 (NG)

    7400 (LP)

    Thermal Efficiency (%) per ANSI Z21.10.3-2015-CSA 4.3-2015 96.8 (NG)

    95.5 (LP)

    95.6 (NG)

    95.8 (LP)

    97.4 (NG)

    95.4 (LP)

    Electrical: 120 VAC, 60 Hz, less than 12 Amp

     

    Model (Heat Exchanger and Boiler Type) 8+4 12+6
    CB-299-HW CB-500-HW
    MIN MAX MIN MAX
    NG MBTU/HR 59 295 98 500
    LP MBTU/HR 59 295 98 500
    Fan Speed (RPM) 1800 (NG)

    1750 (LP)

    6450 2000 7650 (NG)

    7600 (LP)

    Thermal Efficiency (%) per ANSI Z21.10.3-2015-CSA 4.3-2015 97.8 (NG)

    97.6 (LP)

    97.2 (NG)

    95.2 (LP)

    Electrical: 120 VAC, 60 Hz, less than 12 Amp

     

     

  • ANSI Z21.10.3 – 2015 / CSA 4.3 – 2015
  • CSA-2.17-2017
  • Suitable for use with Natural Gas or Propane, for indoor use only.
  • Not to be used with solid fuel.
  • The ventilation of the boiler room must meet local and national standards and regulations, regardless of the selected supply of fresh air to the boiler.
  • The flue gas system must be per the installation manual.
  • Unit must be installed with a certified pressure relief valve supplied by the manufacturer per instructions manual.
  • Water pipes must be approved material for potable water.
  • Project No.: 17241
  • Certificate No.: 17241-1G
Go to Top