Certification Record
LC1230773
Eco Heating Systems Groningen B.V.
2019-09-24
Groningen
Netherlands
DB-80-CH, DB-90-CO, DB-100-CH, DB-120-CH, DB-150-CO, DB-150-CH, DB-180-CH, DB-200-CO
27.060.20, 27.060.30
- Products: Hot Water Supply Boiler
- Model Nos.: DB-80-CH, DB-90-CO, DB-100-CH, DB-120-CH, DB-150-CO, DB-150-CH, DB-180-CH, DB-200-CO
- Ratings:
Model | DB-80-CH | DB-90-CO | DB-100-CH | |||
MAX | MIN | MAX | MIN | MAX | MIN | |
NG MBTU/HR | 80 | 8 | 80 | 9 | 100 | 10 |
LPG MBTU/HR | 80 | 8 | 80 | 9 | 100 | 10 |
Fan Speed (RPM) – NG | 7450 | 1350 | 8300 | 1550 | 6750 | 1300 |
Fan Speed (RPM)- LPG | 6850 | 1400 | 7700 | 1550 | 6450 | 1400 |
Thermal Efficiency (%) per ANSI/ASHRAE 103-2017 | 95.6(NG)
|
95.7 (NG)
|
95.4 (NG)
|
|||
Thermal Efficiency (%) per CAN/CSA P.2 – 13 (R 2017) | 95.7 | 95.7 | 95.5 | |||
Electrical: 120 VAC, 60 Hz, less than 12 Amp |
Model | DB-120-CH | DB-150-CO | DB-150-CH | |||
MAX | MIN | MAX | MIN | MAX | MIN | |
NG MBTU/HR | 120 | 12 | 120 | 15 | 150 | 15 |
LPG MBTU/HR | 120 | 12 | 120 | 15 | 150 | 15 |
Fan Speed (RPM) – NG | 6800 | 1250 | 8000 | 1400 | 7100 | 1300 |
Fan Speed (RPM)- LPG | 6900 | 1350 | 8300 | 1550 | 7150 | 1450 |
Thermal Efficiency (%) per ANSI/ASHRAE 103-2017 | 95.1(NG)
|
95.0 (NG)
|
95.4 (NG)
|
|||
Thermal Efficiency (%) per CAN/CSA P.2 – 13 (R 2017) | 95.2 | 95.0 | 95.5 | |||
Electrical: 120 VAC, 60 Hz, less than 12 Amp |
Model | DB-180-CH | DB-200-CO | ||
MAX | MIN | MAX | MIN | |
NG MBTU/HR | 180 | 18 | 180 | 20 |
LPG MBTU/HR | 180 | 18 | 180 | 20 |
Fan Speed (RPM) – NG | 6900 | 1300 | 7600 | 1400 |
Fan Speed (RPM)- LPG | 6900 | 1350 | 7600 | 1450 |
Thermal Efficiency (%) per ANSI/ASHRAE 103-2017 | 95.2(NG)
|
95.3 (NG)
|
||
Thermal Efficiency (%) per CAN/CSA P.2 – 13 (R 2017) | 95.2(NG) | 95.3(NG) | ||
Electrical: 120 VAC, 60 Hz, less than 12 Amp |
- ANSI Z21.13-2017/ CSA 4.9-2017
- CAN/CSA-P.2-13 (R 2017)
- Suitable for use with Natural Gas or Propane, for indoor use only.
- Not to be used with solid fuel.
- The ventilation of the boiler room must meet local and national standards and regulations, regardless of the selected supply of fresh air to the boiler.
- The flue gas system must be per the installation manual.
- Unit must be installed with a certified pressure relief valve supplied by the manufacturer as per instructions manual.
- Project No.: 17851
- Certificate No.: 17851-2G