LC Clients

Certification Record

LC94447
Critical Environment Technologies Canada Inc.
2019-04-26
British Columbia
Canada
CGAS-D-aaaa-bbbb-oo (digital gas detector), CGAS-A-aaaa-bbbb-oo (analog gas detector)
29.240.30, 13.320
  • Gas Detector
  • Model No(s).: CGAS-D-aaaa-bbbb-oo (digital gas detector)
    CGAS-A-aaaa-bbbb-oo (analog gas detector)
    Where:
    The first group of four characters “aaaa” indicate the gas (sensor) of channel 1 and the second group “bbbb” indicate the gas (sensor) of channel 2 (if included).
    As of April 2018, possible value include but are not limited to:(blank)              no sensor
    NH3                  Ammonia Sensor
    LCO                  Carbon Monoxide sensor
    CL2                   Chlorine Sensor
    CLO2                Chlorine Dioxide Sensor
    C2H4                Ethylene sensor
    EETO                Ethylene oxide
    F2                      Fluorine Sensor
    CH20                Formaldehyde Sensor
    EH2                  Hydrogen sensor
    H2S                  Hydrogen Sulphide sensor
    HCL                  Hydrogen Chloride sensor
    HCN                 Hydrogen Cyanide Sensor
    HF                     Hydrogen Fluoride sensor
    NO                    Nitric Oxide sensor
    NO2A               Nitrogen Dioxide sensor
    O2                     Oxygen sensor
    O3                     Ozone Sensor
    PH3                  Phosphine Sensor
    SIH4                 Silane Sensor
    SO2                  Sulphur dioxide sensor
    CO2                  Carbon Dioxide sensor
    CH2                  Hydrogen Sensor
    CCH4               Methane sensor
    CC3H8             Propane Sensor
    SPL                   TVOC PID sensor (0-30ppm)
    SPH                  TVOC PID sensor (0-300ppm)

    The characters ‘oo’ indicate possible options. Values are:

    IH                      Internal header for cold environment application down to -40C
    S                        Splash Guard (not available with CL2, HCL or O3)
    RHT                  Relative Humidity and temperature sensor
    RLY                   Internal SPDT relay rated 30V @ 2A max (not available with CO2)
    (blank)              Indicating that no options are included on the particular unit.

    • Ratings: 16 – 30Vdc 3W / 12 – 27Vac 50-60Hz 3VA / Class 2
  • CSA-C22.2 No. 205 – 12
  • UL508 (Edition 18): 2018
  • Permanently connected, wall mount, pollution degree 2 and intended to be used indoors in ambient temperature of -40°C to 40°C.
  • Project No. 17037
  • Certificate No. 17037-1S
Go to Top