Certification Record

LC1226231
Industronic® Industrie-Electronic GmbH & Co. KG
2020-11-16
Wertheim
Germany
DX 7x5 Series, DXE 7x5 Series
29.260.20, 35.180
  • Intercom Station
  • Model Nos.: DX 7×5 Series, DXE 7×5 Series
  • Rating:
    – DX 7×5 Series:     Class I Zone 1 Ex db eb ib IIC T4 Gb (*)
    Class I Zone 1 AEx db eb ib IIC T4 Gb (*)
    – DXE 7×5 Series:  Class I Zone 1 Ex db eb ib [ib] IIC T4 Gb (*)
    Class I, Zone 1 AEx db eb ib [ib] IIC T4 Gb (*)
    Uo=7.08 V
    Io=207 mA
    Po=280 mW
    Li – negligible
    Ci=1.3 nF
    – All Models:          Class I, Division 2, Groups A, B, C, D, T4 (*)
    – Input:                   42-72 Vdc, 1A
    – Audio amplifier output: 100 V, 25 W
  • CAN/CSA C22.2 No. 60079-0:19
  • CAN/CSA C22.2 No. 60079-1:16
  • CAN/CSA C22.2 No. 60079-7A:16
  • CAN/CSA C22.2 No. 60079-11:14 (R2018)
  • UL 60079-0 (Ed. 7)
  • UL 60079-1 (Ed. 7)
  • UL 60079-7 (Ed. 5)
  • UL 60079-11 (Ed. 6
  • CAN/CSA C22.2 No. 213-17 / UL 121201 (Ed. 9)
  • CAN/CSA C22.2 No. 62368-1-14
  • UL 62368-1 (Ed. 3)
  • Equipment is intended for use indoors or outdoors in ambient temperature of -40°C to +55°C (-40°C to +70°C for certain models), relative humidity max. 95% (non-condensing), Pollution Degree 2, at altitude up to 2000 m above sea level.
  • Acceptance of the product for use in specified classified locations is based on review of previous evaluation conducted per IECEx Scheme (Certificate IECEx PTB 19.0026X, Test Report DE/PTB/ExTR19.0021/00, and Certificate IECEx PTB 0026X, Issue No: 1, Test Report DE/PTB/ExTR19.0021/01), and evaluation according to respective North American National Deviations.
  • Unit is intended to be powered from and communicate with Digital Communication and Public Address System INTRON-D by Industronic®.
  • Unit is required to be reliably connected to the local equipotential bonding system.

Special conditions for safe use per IECEx PTB 19.0026X and IECEx PTB 19.0026X, Issue No: 1:

  • The intercom station enclosure consists of an electrostatically non-conductive material. A warning note on the type label points to the risk of electrostatic charge.
  • The intercom station shall only be installed in locations where flowing atmospheres (e.g. caused by technical ventilation) do not need to be reckoned with, i.e. charge generating processes shall be prevented.
  • The equipment shall only be cleaned by appropriate measures, i.e. using a damp cloth.
  • The permissible ambient temperature range on the intercom station of type series DXE can be restricted by the use of a separately approved listen/talk-system. The respective ambient temperature range of the separately certified listen/talk system shall be observed.
  • The corresponding torques for the installation of cable glands and enclosure cover must be observed and taken from the operating instructions manual.
  • Project No. LV-15027
  • Certificate No. 15027-1S

 