Certification Record
LC1234259
Canada Sensors Technology Inc.
2021-01-29
BC
Canada
Process 4; Process 4 HYD; Process 6; Process 6 HYD; Process 9 – IS; Process 9 - IS - HYD
17.100, 29.260.20
- Pressure Transmitters
- Model Nos.: Process 4; Process 4 HYD; Process 6; Process 6 HYD; Process 9 – IS; Process 9 – IS – HYD
- Rated:
- CI D2 Grp ABCD Class I Zone 2
- AEx ec IIC T4 Gc, Ex ec IIC T4 Gc
- 10 to 28Vdc, IP65, -40°C to +95°C
- -30”Hg Vac to 30000 PSI or 1 to 200 PSID
- 10-28VDC, 5 ma
- CSA C22.2 NO. 213-17/ UL 121201 (Ed 9),
- CSA-C22.2 NO. 61010-1-12 (R2017)/ UL 61010-1 (Ed 3)
- CSA-C22.2 NO. 60079-0:19; CSA-C22.2 NO. 60079-7A;16,
- UL 60079-0 (Ed 7); UL 60079-7 (Ed 5)
- Installation to be permanently connected, Pollution Degree 4 or better, Overvoltage Category I.
- Not evaluated for use with flammable fluids.
- Powered by certified Class 2 Power Supply as defined in the Canadian Electrical Code or National Electrical Code or by a CSA C22.2 No.60950 -1/ UL 60950-1 certified limited power source (LPS).
- Wiring end must be installed in conduit or other enclosure providing IP65 ingress protection.
- Models with DIN 43650A connector (nomenclature 22) are limited to Class I and not to be used for Class II applications.
- Installation must include protection from impact greater than 4 joules.
General Notes:
- Project No. 19352
- Certificate No. LC21CA19352X
- Listing Report No. 11.00.19352-1_Rev0