Clients

Certification Record

LC1234079
Infiniti Fire
2021-02-10
Arizona
United States
Infiniti Series - 240, 300, 360, 420, 480, 540, 600, 660, 720, 780, 840, 900, 960, 1020, 1080, 1140, 1200, 1260, 1320, 1380, 1440
97.100.20
  • Vented Decorative Gas Fireplaces
  • Series Name: Infiniti Series
  • Model Nos.: 240, 300, 360, 420, 480, 540, 600, 660, 720, 780, 840, 900, 960, 1020, 1080, 1140, 1200, 1260, 1320, 1380, 1440

+ Each model shall have a suffix based on the specific option:

SYM – symmetric style

STH – see-through style

OEL – open end left style

OER – open end right style

BAY – open both ends style

PEN – peninsula style

GLF – glass front style

OVL – outdoor ventless style

  • Ratings:
    • Electrical – Electronic Ignition Pilot System: 24 Vac, 60 Hz, less than 2 Amps
    • Electrical – Millivolt Standing Pilot System: Millivolt only; no electrical ratings
    • Gas Ratings: See below
Model Natural Gas Rating – 3.8” water column manifold pressure Propane Gas Rating – 11” water column manifold pressure
240 30,000 BTU/hr 30,000 BTU/hr
300 45,000 BTU/hr 45,000 BTU/hr
360 60,000 BTU/hr 60,000 BTU/hr
420 75,000 BTU/hr 75,000 BTU/hr
480 90,000 BTU/hr 90,000 BTU/hr
540 105,000 BTU/hr 105,000 BTU/hr
600 120,000 BTU/hr 120,000 BTU/hr
660 135,000 BTU/hr 135,000 BTU/hr
720 150,000 BTU/hr 150,000 BTU/hr
780 165,000 BTU/hr 165,000 BTU/hr
840 180,000 BTU/hr 180,000 BTU/hr
900 195,000 BTU/hr 195,000 BTU/hr
960 210,000 BTU/hr 210,000 BTU/hr
1080 225,000 BTU/hr 225,000 BTU/hr
1140 240,000 BTU/hr 240,000 BTU/hr
1200 255,000 BTU/hr 255,000 BTU/hr
1260 270,000 BTU/hr 270,000 BTU/hr
1320 285,000 BTU/hr 285,000 BTU/hr
1380 300,000 BTU/hr 300,000 BTU/hr
1440 315,000 BTU/hr 315,000 BTU/hr
  • ANSI Z21.50-2019 / CSA 2.22-2019
  • ANSI Z21.97-2017 / CSA 2.41-2017
  • The Infiniti Series models require 12” of noncombustible surfaces surrounding the exposed face of the unit.
  • Outdoor ventless models, denoted by OVL model name suffix, are approved for outdoor use only.
  • The Infiniti series models shall be connected and remain connected to a listed venting system according to manufacturer’s instructions and in accordance with local codes.

General Notes:

  • Project No. LV-15031
  • Listing Report No. 50.02.14199-1_Rev2
  • Certificate No. LC50.02.14199-1
Go to Top