Clients

Certification Record

LC1231357
EVTeam Corp.
2021-04-12
Ontario
Canada
FLD-MXM-xxx, FLD-420-xxx, FLD-702-xxx, FLD-F4RTD-xxx, FLD-T3RTD FLD- F4XPULS-xxx, FLD-T3XPULS, FLD-FBS-xxx
29.260.20
  • Field Sensor Boxes
  • Model Nos.: FLD-MXM-xxx, FLD-420-xxx, FLD-702-xxx, FLD-F4RTD-xxx, FLD-T3RTD, FLD- F4XPULS-xxx, FLD-T3XPULS, FLD-FBS-xxx
  • Ratings:
  • – For FLD-MXM-xxx, FLD-420-xxx, FLD-702-xxx and FLD-FBS-xxx:
      • Ex ia IIB T4 -40°C ≤ Ta ≤ +80°C
      • Class I Zone Ex ia IIB T4 -40°C ≤ Ta ≤ +80°C
      • Class I, Division 1 Group C D T4 -40°C ≤ Ta ≤ +80°C
  • – For FLD-T3RTD-xxx and FLD-T3XPULS-xxx:
      • Ex ia IIB T3 -40°C ≤ Ta ≤ +80°C
      • Class I Zone Ex ia IIB T3 -40°C ≤ Ta ≤ +80°C
      • Class I, Division 1 Group C D T3 -40°C ≤ Ta ≤ +80°C
  • – For FLD-F4RTD-xxx and FLD-F4XPULS-xxx:
      • Ex ia IIB T4 -40°C ≤ Ta ≤ +60°C
      • Class I Zone Ex ia IIB T4 -40°C ≤ Ta ≤ +60°C
      • Class I, Division 1 Group C D T4 -40°C ≤ Ta ≤ +60°C

Model: FLD-MXM-xxx
Supply: Input:12-20Vdc and Output: 12-20Vdc
Ui=22V; li=150mA; Pi=1W; Ci,Li=0

Model: FLD-420-xxx
Supply: Input:12-24Vdc and Output: 5Vdc
Ui=28V; li=150mA; Pi=1W; Ci,Li=0

Model: FLD-702-xxx
Supply: Input:5-20Vdc and Output: 3.6Vdc
Ui=22V; li=150mA; Pi=1W; Ci,Li=0

Model: FLD-F4RTD-xxx and FLD-T3RTD-xxx
Supply: Input:3.6Vdc and Output: 3.6Vdc
Ui=10V; li=300mA; Pi=0.3W; Ci,Li=0

Model: FLD-F4XPULS-xxx and FLD-T3XPULS-xxx
Supply: Input:3.6Vdc and Output: 3.6Vdc
Ui=10V; li=300mA; Pi=0.3W; Ci,Li=0

Model: FLD-FBS-xxx
Supply: Input:12-20Vdc and Output: 5Vdc
Ui=22V; li=150mA; Pi=1W; Ci,Li=0

  • CSA-C22.2 No. 61010-1-12:2012(R2017) / UL61010-1(Edition 3):2012
  • CSA-C22.2 No. 157-92 (R2016)
  • UL 913(Ed 8)
  • None

General Note:

  • Project No. 16603
  • Report No. 11.00.16603-1_Rev1
  • Certificate No. LC16603-1
Go to Top