Clients

Certification Record

LC1234263
DAKO Sp. z o.o.
2022-01-24
Poland
Fixed Lite – Series DA-77
91.060.50
  • Fixed Lite – Series DA-77
  • Performance Class/ Performance Grade Rating: AW60
  • Thermal simulation performed for four different triple glazing options.
  • Model number(s) will be created according to the next following coding system: DA-77FXD-IGXX

Legend for Coding System and Energy Performance Values:

  • DA-77FXD – Product identifier for Fixed Lite – Series DA-77
  • IGXX – Glazing option where ‘XX’ is replaced by a two-digit number (i.e. ‘01’)

Glazing Options:

  • Option 01: 4mm Planitherm XN / 18mm 90% Argon / 4mm Planitherm XN / 18mm 90% Argon / 4mm Planitherm XN: U factor: 1.1; Solar Heat Gain Coefficient: 0.41; Visible Transmittance: 0.62; Air Leakage: 0.1; Energy Rating: 39.
  • Option 02: 4mm Planitherm XN II / 18mm 90% Argon / 4mm Planitherm XN II / 18mm 90% Argon / 4mm Planitherm XN II: U factor: 1.08; Solar Heat Gain Coefficient: 0.41; Visible Transmittance: 0.62; Air Leakage: 0.1; Energy Rating: 40.
  • Option 03: 6mm Planitherm XN II / 14mm 90% Argon / 6mm Planitherm XN II / 16mm 90% Argon / 6mm Planitherm XN II: U factor: 1.07; Solar Heat Gain Coefficient: 0.4; Visible Transmittance: 0.61; Air Leakage: 0.1; Energy Rating: 39.
  • Option 04: 8.4mm Planitherm XN lami44-1 / 16mm 90% Argon / 4mm Planitherm XN II / 16mm 90% Argon / 4mm Planitherm XN II: U factor: 1.08; Solar Heat Gain Coefficient: 0.39; Visible Transmittance: 0.61; Air Leakage: 0.1; Energy Rating: 38.
  • AAMA/WDMA/CSA 101/I.S.2/A440-17
  • AAMA/WDMA/CSA 101/I.S.2/A440.2-19
  • AAMA/WDMA/CSA 101/I.S.2/A440.3-2019 – User Guide for CSA 101/I.S.2/A440.2-19
  • Products are certified for Canadian Market only, with applicable restrictions based on Energy Star Zone Requirements

General Note:

  • Refer to LC Listing Report no. 40.00.15102-2_Rev0
Go to Top