LC1225077
Acucraft Fireplaces
2021-10-14
Minnesota
United States
HR-36-SS, HR-44-SS, HR-48-SS, HR-36-ST, HR-44-ST, HR-48-ST, HR-36-IO, HR-44-IO, HR-48-IO
97.100.30
  • Factory Built Fireplaces
  • Series:
    • Hearthroom Series
  • Models:
    • Single Sided Models: HR-36-SS, HR-44-SS, HR-48-SS
    • See Through Models: HR-36-ST, HR-44-ST, HR-48-ST
    • Indoor/Outdoor Models: HR-36-IO, HR-44-IO, HR-48-IO

+ All models have option of mantel configurations of rectangular and arched. Rectangular options will be denoted by suffix “REC” and arched denoted by suffix “ARC”

  • Ratings:
    • Solid Fuel Ratings
      • All models
        • Solid fuel: wood logs or composite fire logs approved to ANSI/CAN/UL/ULC 2115 – Processed Solid Fuel Firelogs and Firestarters
    • Gas Log Set Configuration Ratings:
      • HR-36-SS:
        • 76k BTU/hr NG at 3.5” water column manifold pressure
        • 79k BTU/hr LP at 10” water column manifold pressure
      • HR-44-SS
        • 81k BTU/hr NG at 3.5” water column manifold pressure
        • 83k BTU/hr LP at 10” water column manifold pressure
      • HR-48-SS
        • 86k BTU/hr NG at 3.5” water column manifold pressure
        • 87k BTU/hr LP at 10” water column manifold pressure
      • HR-36-ST, HR-36-IO
        • 128k BTU/hr NG at 3.5” water column manifold pressure
        • 115k BTU/hr LP at 10” water column manifold pressure
      • HR-44-ST, HR-44-IO
        • 135k BTU/hr NG at 3.5” water column manifold pressure
        • 125k BTU/hr LP at 10” water column manifold pressure
      • HR-48-ST, HR-48-IO
        • 140k BTU/hr NG at 3.5” water column manifold pressure
        • 125k BTU/hr LP at 10” water column manifold pressure
  • Electrical (all models): 120 Vac, 60 Hz, 1 Amp
  • UL 127 (Ed 9): 2011
  • CAN/ULC S610:2018
  • All models shall be connected to a listed venting system as specified by manufacturer and in accordance with local codes.
  • Solid fuel approved fuels are solid wood logs and composite fire logs. Composite fire logs must be approved to ANSI/CAN/UL/ULC 2115.
  • Models configured for use with a gas log set shall use only approved log set burners only; approved to ANSI/IAS/AGA Z21.11.2

General Notes:

  • Project no.: LV-15357
  • LC Listing Report no.: 50.02.15026-1_Rev.1
  • LC Certificate no.: LC15026-1