Clients

Certification Record

LC1226220
Gastops Ltd.
2022-07-21
Ontario
Canada
MS4000
29.260.20
  • MetalSCAN System
  • Model Nos.: MS4000
  • Ratings:
    • Voltage: 18-30 Vdc
    • Power: 13 W
    • -40°C ≤ Ta ≤ 55°C
    • Canada Marking: Class I Div 2 Groups A-D
    • US Marking:  Class I, Zone 2, AEx ec IIB T4 Gc
    • Sensors:            -40°C ≤ Ta ≤ 190°C; T3
  • CAN/CSA-C22.2 No. 61010-1A-12 Amendment 1:2018 to CAN/CSA-C22.2 No. 61010-1-12
  • UL 61010-1 and ANSI/ISA-61010-1 (82.02.01)
  • CSA C22.2 No. 213-17/ UL 121201 (Ed. 9)
  • UL 60079-0 (Ed. 7)
  • UL 60079-7 (Ed. 5)
  • Provisions shall be made external to the equipment to limit the transient voltage
  • Degree of protection (IP66) must be maintained during installation by end user.
  • Warning for Electrostatic discharge: potential electrostatic charging hazard – see instruction manual.

General Note:

  • Rev.0 – Issued March 10, 2015
  • Rev.1 – Issued August 03, 2016
  • Rev.2 – Issued April 18, 2017
  • Rev.3 – Issued June 26, 2022
      • Updating the standards for LC certification for Models: MS 4000 (previously evaluated in LabTest’s projects 11929, 11930 and 16237) and testing conducted in this project.
      • Evaluating and assessment for change in protection method from “nA to ec” for US Market only.
      • Updating drawings
Go to Top