LC Clients

Certification Record

LC1231751
Victron Energy B.V.
2022-09-20
Almere
Netherlands
MultiPlus-II 12/3000/120-50 120V, MultiPlus-II 24/3000/70-50 120V, MultiPlus-II 24/3000/70-50 2x120V, MultiPlus-II 48/3000/35-30 120V
29.200
  • Inverter
  • Model Nos.:
    • MultiPlus-II 12/3000/120-50 120V
    • MultiPlus-II 24/3000/70-50 120V
    • MultiPlus-II 24/3000/70-50 2x120V
    • MultiPlus-II 48/3000/35-30 120V
  • Ratings:
    Model/Type(s): MultiPlus-II 12/3000/120-50 120V
    Rating and main characteristics: 12/3000/120-50

    120V

    INVERTER
    Input voltage range (V DC) 9,5 – 17
    Output Output voltage: 120 VAC ± 2%

    Frequency: 60 Hz ± 0,1%

    Cont. output power at 25°C (VA) (nonlinear load, crest factor 3:1) 3000
    Cont. output power at 25°C (W) 2400
    Cont. output power at 40°C (W) 2200
    Cont. output power at 65°C (W) 1700
    Peak power (W) 5500
    CHARGER
    AC Input Single phase: 90-140 VAC 45 – 65 Hz
    Charge voltage ‘absorption’ (V DC) 14.4
    Charge voltage ‘float’ (V DC) 13.8
    Storage mode (V DC) 13.2
    Charge current house battery (A) (at 25°C ambient) 120
    Model/Type(s): MultiPlus-II 24/3000/70-50 120V
    Rating and main characteristics: 24/3000/70-50

    120V

    INVERTER
    Input voltage range (V DC) 19 – 33
    Output Output voltage: 120 VAC ± 2%

    Frequency: 60 Hz ± 0,1% (can be adjusted to 50Hz)

    Cont. output power at 25°C (VA) (nonlinear load, crest factor 3:1) 3000
    Cont. output power at 25°C (W) 2400
    Cont. output power at 40°C (W) 2200
    Cont. output power at 65°C (W) 1700
    Peak power (W) 5500
    CHARGER
    AC Input Single phase: 90-140 VAC 45 – 65 Hz
    Charge voltage ‘absorption’ (V DC) 28.8
    Charge voltage ‘float’ (V DC) 27.6
    Storage mode (V DC) 26.4
    Charge current house battery (A) (at 25°C ambient) 70
    Model/Type(s): MultiPlus-II 24/3000/70-50 2x120V
    Rating and main characteristics: 12-3000-120-50

    2x120V

    INVERTER
    Input voltage range (V DC) 19 – 33
    Output Output voltage: 120 VAC ± 2%

    Frequency: 60 Hz ± 0,1% (can be adjusted to 50Hz)

    Cont. output power at 25°C (VA) (nonlinear load, crest factor 3:1) 3000
    Cont. output power at 25°C (W) 2400
    Cont. output power at 40°C (W) 2200
    Cont. output power at 65°C (W) 1700
    Peak power (W) 5500
    CHARGER
    AC Input Split phase: 180-280 VAC 45 – 65 Hz

    Single phase: 90-140 VAC 45 – 65 Hz

    Charge voltage ‘absorption’ (V DC) 28.8
    Charge voltage ‘float’ (V DC) 27.6
    Storage mode (V DC) 26.4
    Charge current house battery (A) (at 25°C ambient) 70
    Model/Type(s): MultiPlus-II 48/3000/35-30 120V
    Rating and main characteristics: 48/3000/35-30

    120V

    INVERTER
    Input voltage range (V DC) 38 – 66
    Output Output voltage: 120 VAC ± 2%

    Frequency: 60 Hz ± 0,1% (can be adjusted to 50Hz)

    Cont. output power at 25°C (VA) (nonlinear load, crest factor 3:1) 3000
    Cont. output power at 25°C (W) 2400
    Cont. output power at 40°C (W) 2200
    Cont. output power at 65°C (W) 1700
    Peak power (W) 5500
    CHARGER
    AC Input Split phase: 180-280 VAC 45 – 65 Hz

    Single phase: 90-140 VAC 45 – 65 Hz

    Charge voltage ‘absorption’ (V DC) 57.6
    Charge voltage ‘float’ (V DC) 55.2
    Storage mode (V DC) 52.8
    Charge current house battery (A) (at 25°C ambient) 35
  • UL 458 6th Edition

Conditions of acceptability:

  • None

General Note:

  • Project no. 20469B
  • LC Listing Report no. 10.00.20469-3_Rev.0
  • LC Certificate no. LC20469-3