24-See-Through, 30-See-Through, 36-See-Through, 42-See-Through, 48-See-Through, 24-Single Side, 30-Single Side, 36-Single Side, 42-Single Side, 48-Single Side
97.100.20
- Decorative Vented Gas Logsets
- Models:
- Single Sided Models: 24”-Single Side, 30”-Single Side, 36”-Single Side, 42”-Single Side, 48”-Single Side
- See Through Models: 24”-See-Through, 30”-See-Through, 36”-See-Through, 42”-See-Through, 48”-See-Through
- Ratings:
- Model: 24”-See-Through
- Natural Gas Max: 70,000 BTU/hr at 3.5” water column manifold pressure
- Propane Max: 70,000 BTU/hr at 10.0” water column manifold pressure
- Model: 30”-See-Through
- Natural Gas Max: 124,000 BTU/hr at 3.5” water column manifold pressure
- Propane Max: 124,000 BTU/hr at 10.0” water column manifold pressure
- Model: 36”-See-Through
- Natural Gas Max: 150,000 BTU/hr at 3.5” water column manifold pressure
- Propane Max: 150,000 BTU/hr at 10.0” water column manifold pressure
- Model: 42”-See-Through
- Natural Gas Max: 177,000 BTU/hr at 3.5” water column manifold pressure
- Propane Max: 177,000 BTU/hr at 10.0” water column manifold pressure
- Model: 48”-See-Through
- Natural Gas Max: 203,000 BTU/hr at 3.5” water column manifold pressure
- Propane Max: 203,000 BTU/hr at 10.0” water column manifold pressure
- Model: 24”-See-Through
-
- Model: 24”-Single Side
- Natural Gas Max: 56,000 BTU/hr at 3.5” water column manifold pressure
- Propane Max: 56,000 BTU/hr at 10.0” water column manifold pressure
- Model: 30”- Single Side
- Natural Gas Max: 73,000 BTU/hr at 3.5” water column manifold pressure
- Propane Max: 73,000 BTU/hr at 10.0” water column manifold pressure
- Model: 36”- Single Side
- Natural Gas Max: 91,000 BTU/hr at 3.5” water column manifold pressure
- Propane Max: 91,000 BTU/hr at 10.0” water column manifold pressure
- Model: 42”- Single Side
- Natural Gas Max: 108,000 BTU/hr at 3.5” water column manifold pressure
- Propane Max: 108,000 BTU/hr at 10.0” water column manifold pressure
- Model: 48”- Single Side
- Natural Gas Max: 126,000 BTU/hr at 3.5” water column manifold pressure
- Propane Max: 126,000 BTU/hr at 10.0” water column manifold pressure
- Model: 24”-Single Side
- Electrical (all models): 120 Vac, 60 Hz, 2 Amps max
- ANSI Z21.60-2017 / CSA 2.26-2017
- CSA 2.17:2017
- All models shall be installed in a vented fireplace only that is connected to a listed venting system as specified by manufacturer and in accordance with local codes.
General Notes:
- Project no.: LV-15950
- LC Listing Report no.: 50.02.15950-1_Rev.0
- LC Certificate no.: LC15950-1