Acucraft Fireplaces
2022-12-20
Minnesota
United States
24-See-Through, 30-See-Through, 36-See-Through, 42-See-Through, 48-See-Through, 24-Single Side, 30-Single Side, 36-Single Side, 42-Single Side, 48-Single Side
97.100.20
  • Decorative Vented Gas Logsets
  • Models:
    • Single Sided Models: 24”-Single Side, 30”-Single Side, 36”-Single Side, 42”-Single Side, 48”-Single Side
    • See Through Models: 24”-See-Through, 30”-See-Through, 36”-See-Through, 42”-See-Through, 48”-See-Through
  • Ratings:
    • Model: 24”-See-Through
      • Natural Gas Max: 70,000 BTU/hr at 3.5” water column manifold pressure
      • Propane Max: 70,000 BTU/hr at 10.0” water column manifold pressure
    • Model: 30”-See-Through
      • Natural Gas Max: 124,000 BTU/hr at 3.5” water column manifold pressure
      • Propane Max: 124,000 BTU/hr at 10.0” water column manifold pressure
    • Model: 36”-See-Through
      • Natural Gas Max: 150,000 BTU/hr at 3.5” water column manifold pressure
      • Propane Max: 150,000 BTU/hr at 10.0” water column manifold pressure
    • Model: 42”-See-Through
      • Natural Gas Max: 177,000 BTU/hr at 3.5” water column manifold pressure
      • Propane Max: 177,000 BTU/hr at 10.0” water column manifold pressure
    • Model: 48”-See-Through
      • Natural Gas Max: 203,000 BTU/hr at 3.5” water column manifold pressure
      • Propane Max: 203,000 BTU/hr at 10.0” water column manifold pressure
    • Model: 24”-Single Side
      • Natural Gas Max: 56,000 BTU/hr at 3.5” water column manifold pressure
      • Propane Max: 56,000 BTU/hr at 10.0” water column manifold pressure
    • Model: 30”- Single Side
      • Natural Gas Max: 73,000 BTU/hr at 3.5” water column manifold pressure
      • Propane Max: 73,000 BTU/hr at 10.0” water column manifold pressure
    • Model: 36”- Single Side
      • Natural Gas Max: 91,000 BTU/hr at 3.5” water column manifold pressure
      • Propane Max: 91,000 BTU/hr at 10.0” water column manifold pressure
    • Model: 42”- Single Side
      • Natural Gas Max: 108,000 BTU/hr at 3.5” water column manifold pressure
      • Propane Max: 108,000 BTU/hr at 10.0” water column manifold pressure
    • Model: 48”- Single Side
      • Natural Gas Max: 126,000 BTU/hr at 3.5” water column manifold pressure
      • Propane Max: 126,000 BTU/hr at 10.0” water column manifold pressure
  • Electrical (all models): 120 Vac, 60 Hz, 2 Amps max
  • ANSI Z21.60-2017 / CSA 2.26-2017
  • CSA 2.17:2017
  • All models shall be installed in a vented fireplace only that is connected to a listed venting system as specified by manufacturer and in accordance with local codes.

General Notes:

  • Project no.: LV-15950
  • LC Listing Report no.: 50.02.15950-1_Rev.0
  • LC Certificate no.: LC15950-1