Certification Record
- Canned Motor Pumps
- Ratings:
- 180 – 690 Vac, 25 – 60 Hz, 1.4 – 660 Amps, 0.75 – 315 Kw
- – 40oC to 60oC
- Class I Zone 1
- Ex db IIC T1-T4
- AEx db IIC T1-T4
- IP 66
- Model Nomenclature: H/S/C series
_ _ _ _ _ _ _-_ _ _ __ (__ __ __) __ /_ _ _ _ _ _ _ _ – _ __ __ __ __
1 2 3 4 5 6 7 – 8 9 10 11 (12 13 14) 15 / 1 2 3 4 5 6 7 8 – 9 10 11 12 13
Pump Section:
Position 1 – Canned motor pump series
H – Standard chemical canned motor pump
S – Centerline mounted canned motor pump
C – Foot mounted canned motor pump
Positions (2 to 4) – Circulation plans for H/S/C Series
Note: Circulation plans are not relevant to the explosion proof designs. Examples of circulation plans are listed but not limited to below.
P – External recirculation basic type
PA – External recirculation basic type with adapter
PP – External pressurized type
V – Internal recirculation basic type
VA – Internal recirculation basic type with adapter
N – Reverse recirculation type
NA – Reverse recirculation type with adapter
NAP – Pressurized reverse recirculation type with adapter
T – High temperature type
Z – Self-priming type
R – High-melting-point type
W – Vertical reverse circulation type
WAP – Vertical pressurized reverse recirculation type with adapter
S – Slurry type with mechanical seal
F – Slurry type with back flush
M – Slurry type with metering pump
E – Submerged type
NP – Internal pressurized type
Positions (5 to 7) Nominal suction nozzle dia. in mm
Note: Suction nozzle sizes are not relevant to the explosion proof assessment.
Positions (8 to 10) Nominal discharge nozzle dia. in mm
Note: Discharge nozzle sizes are not relevant to the explosion proof assessment.
Position 11 – Nominal impeller sizes
Note: Nominal impeller sizes are not relevant to the explosion proof assessment. Examples of impeller sizes are listed but not limited to below.
A – 100mm; B – 125mm; C – 160mm; D – 200mm;
E – 260mm; F – 315mm; G – 400mm; H – 480mm;
J – 540mm; L – Other sizes.
Position 12 – Pump construction type
Note: Pump construction types are not relevant to the explosion proof assessment. Examples of pump construction types are listed but not limited to below.
- a) None – Standard single stage
- b) M – Multistage
- c) S – Smaller sized impeller
- d) Other – special design impellers
Positions (13 to 14) – Stages for multistage pump
Position 15 – Casing types
Note: Casing types are not relevant to the explosion proof assessment. Examples of casing types are listed but not limited to below.
None – Standard; J – Partially jacketed; Q – Fully jacketed
Motor Section:
Positions (1 to 4) – Motor frame sizes
Frame 110 – 115
Frame 210 – 212, 214
Frame 220 – 222
Frame 310 – 312, 314
Frame 320 – 321, 322
Frame 410 – 412, 415
Frame 420 – 421, 422
Frame 510 – 512, 514
Frame 520 – 521, 522
Frame 530 – 531, 532
Frame 610 – 612, 615
Frame 620 – 621, 622, 624
Frame 630 – 631, 632
Frame 710 – 712, 714
Frame 720 – 722, 724
Frame 730 – 732, 733, 734
Frame 810 – 813, 814
Frame 820 – 822, 825
Frame 910 – 912, 913
Frame 920 – 922, 923, 925
Position 5 – Motor insulation class
C – Class 200; S – Class 200 with jacket;
Note – Standard 100 boundary is class H. table 4 & 10 of CSA 100. If you reach 195C & insulation is good for 200, motors cannot get hotter. Limit of the motor temp will be 180C.
Insulation classes will be assessed to class H as per maximum in the standards. Our report will spell out all insulations used, but our assessment will use the limits of class H.
Position 6 – Nominal supply voltage
- 2 – 180~260V;
- 4 – 300~480V;
- 6 – 500~690V;
Position 7 – Starting method and thermal protection
B – DOL + Thermostat; P – DOL + Others;
E – Star-Delta + Thermostat;
Q – Star-Delta + Others;
F – Inverter + Thermostat;
R – Inverter + Others
Position 8 – HPB monitor type
Note: HBP circuitry is included in all versions.
None – Local mounted; L – Remote control;
Position 9 – Frequency and inducer
Note: Inducer is an impeller type and is not relevant to the explosion proof assessment, but frequency is.
B – 50Hz+No inducer; F – 50Hz+Inducer
A – 60Hz+No inducer; E – 60Hz+Inducer
Positions (10-11) – Design pressure in MPa
Note: Design pressure of the pump impacts inner part of the can thickness, the lowest rated pressure unit has the thinnest wall and greatest Ex d volume.
Position 12 – Bearing material
Note: Bearing materials are not relevant to the explosion proof assessment. Examples of bearing materials are listed but not limited to below.
C – Standard C.G.; H – Super hardened C.G.;
K – High temp. C.G.; S – SiC; E – Others
Position 13 – Wet end material
Note: Wet end materials are not relevant to the explosion proof designs. Examples of wet end materials are listed but not limited to below.
1 – Cast Iron; 2 – Cast Steel; 3 – ZG1Cr18Ni9;
4 – 304SS; 5 – 304L; 6 – 316SS; 7 – 316L; 9 – Others
- UL 60079-0: Ed 7
- UL 60079-1: Ed 7
- UL 1004-1: Ed 2, 2012
- CAN/CSA C22.2 No. 60079-0: 2019
- CAN/CSA C22.2 No. 60079-1: 2016
- CAN/CSA C22.2 No. 108: 14 (R 2024)
- CAN/CSA C22.2 No. 100:14 (R 2024)
- Don’t run the motor dry
- Any repair of the flameproof gaps is only allowed according to the instruction given by original manufact
- Refer to the instruction manual of the manufacturer during installation and commissioning
General Note:
- Ties to the main listing no. LC15441-1
- LC Multiple Listing Certificate no.: LC15441-1-ML1