Certification Record
LC 1250027
Pathway Industries Inc.
2026-06-11
British Columbia
Canada
SILO
- Pressure Swing Adsorption System
- Model No.: SILO
- Ratings:
- Ex II 3 G Ex ec db h IIB+H2 T3 Gc
- 400Vac, 1.5Amps, 50Hz, 3PH
- Control: 24VDC, 0.5A
- EN IEC 60079-0:2018
- EN 60079-7:2015/A11:2024
- EN 60079-1:2014
- EN ISO 80079-36:2016
- EN ISO 80079-37:2016
- Cable glands for wiring installation shall be suitably-certified and shall maintain the minimum IP54 ingress protection of the enclosure.
- End users shall follow specific installation and operating instructions supplied by the manufacturer to prevent exceeding the heat dissipating limits for the desired temperature code for an operating ambient.
- Motor shall be supplied by an external VFD, model MCX91A-0010-5E3-4-T00/001, located in a non-hazardous area only. It is the end user’s responsibility to follow the instructions provided for connection of the VFD to the motor and to ensure all applicable requirements are met.
- Under certain extreme circumstances, the non-metallic parts incorporated in the enclosure of this equipment may generate an ignition-capable level of electrostatic charge. Therefore, the equipment shall not be installed in a location where the external conditions are conducive to the build-up of electrostatic charge on such surfaces. In addition, the equipment shall only be cleaned with a damp cloth.
- Unused entry holes for the enclosure shall be fitted with suitable stopping plugs having an equipment certificate or having a component certificate subject to the confirmation by the end user/installer of the ingress protection rating and the permitted service temperature of the component.
- The end user is to ensure appropriate earthing upon installation.
General Note.:
- Project no.: 25-5630
- ATEX Test Report Cover: 11.03.25-5630-1
- ATEX CAT 3 Unit Verification Certificate no.: LC26ATEX25-5630-1X, Issue 0