Certification Record
LC1229903
Combustion and Energy S. r. l.
2022-06-10
Lecco
Italy
EJBS-A, EJBS-B, EJBS-C, EJBS-D, EJBS-E, EJBS-F, EJBS-G, EJBS-H and EJB-A, EJB-B, EJB-C, EJB-D, EJB-E, EJB-F, EJB-G, EJB-H
21.180
- Enclosures
- Model Nos.:
- EJBS (Stainless Steel) Series Enclosures without windows
EJBS-A, EJBS-B, EJBS-C, EJBS-D, EJBS-E, EJBS-F, EJBS-G, EJBS-H
- EJBS (Stainless Steel) Series Enclosures without windows
-
- EJBA (Aluminium) Series Enclosures without windows
EJB-A, EJB-B, EJB-C, EJB-D, EJB-E, EJB-F, EJB-G, EJB-H.
- EJBA (Aluminium) Series Enclosures without windows
- Rating:
- Ex db IIB+H2 T6/T5/T4 Gb
- Class I Zone 1 AEx db IIB+H2 T6/T5/T4 Gb
- Ex tb IIIC T85°C / T100°C / T135°C Db IP66/IP67
- Class II Zone 21 AEx tb IIIC T85°C/T100°C/T135C Db
- Ambient Temperature: -50°C to +60°C
- Zone 1 and Zone 21
- CSA C22.2 No. 60079-0:19
- CSA C22.2 No. 60079-1:16
- CSA C22.2 No. 60079-31:15
- UL 60079-0, Ed. 7
- UL 60079-1, Ed. 7
- UL 60079-31, Ed. 2
Condition of Acceptability/Scheduled of Limitations for Ex Components:
- This certification is for empty Stainless steel/ Aluminum enclosures only.
- The content of the Ex-component enclosure equipment may be placed in any arrangement, provided that, for group IIB and IIB+H2 an area of at least 40% of each cross-sectional area remains free.
- The accessories used for cable entries and for closing unused openings shall be certified according to UL 60079-0 and CSA C22.2 No. 60079-0, UL 60079-1, CSA C22.2 No 60079-1 and, UL 60079-31 and CSA C22.2 No 60079-31. A minimum degree of protection IP66 (with operators installed) and IP67 (without operators installed) shall be guaranteed according to CSA C22.2 No. 60529: 2016 (R2021) standard.
Specific Conditions of Use:
- THIS EQUIPMENT SHALL BE INSTALLED SO THAT THE FLANGED JOINT(S) ARE NOT WITHIN (40 mm) OF A SOLID OBJECT THAT IS NOT PART OF THIS EQUIPMENT. i.e. THE MINIMUM DISTANCE BETWEEN FLAMEPROOF FLANGED JOINT OF THE ENCLOSURE AND EXTERNAL OBSTACLE SHOULD BE 40 mm FOR IIB+H2 EXECUTION.
- SEAL SHALL BE PROVIDED WITHIN 50 mm OF THE THREADED CONDUIT.
- THE COVER FIXING SCREWS IF REPLACED, SHOULD BE OF SAME TYPE OR BETTER QUALITY IN TERMS OF TENSILE STRENTH AND YIELD STRESS i.e. Use screws of quality (A4-70) with tensile strength of at least 700 N/mm2 .
General Note:
- Refer to LC Listing Report No. 11.00.15427-1_Rev0