Programma di certificazione DPI

Non-Powered Air Purifying Respirators

Ottieni un preventivo gratuito
Mentre il modo più efficace per fermare un virus è quello di mantenere distanziamento fisico e una corretta igiene delle mani, the use of face masks can help the person wearing the mask to not spread infected droplets to others and also to self-protect from inhaling incoming viral particles from others.

CONFORMITÀ SALUTE CANADA E NIOSH

LabTest Certification offers Airflow Resistance and Particulate Filtration Efficiency (Pfe) for Certification of Non-Powered Air-Purifying Respiratori, come N95, N99, e N100, in base ai requisiti fissati da Health Canada e dal National Institute for Occupational Safety and Health (Niosh).

Durante la pandemia globale COVID-19, come il mondo vede un aumento della domanda di Personal Protective Equipment (Ppe), and specifically for face masks, third-party approval of protective equipment is critical to ensure that it meets the required safety specifications, prima di essere indo ai dati sul mercato. LC compliance reports provide manufacturers of respirators with the validation that their product provides the minimum level of protection against the intended risk.

How to choose the right mask?

Ci sono diversi tipi di maschere protettive disponibili sul mercato, come reusable (Tessuto) Maschere, maschere chirurgiche, e respirators. L'efficienza della filtrazione varia tra le maschere in base a molti fattori diversi.

Che cos'è un Respiratore?

Poiché il Coronavirus outbreak continues, tutti abbiamo familiarmente con le maschere protettive, especially the N95 respirators. Compared with other types of protective masks, Respiratori N95 are designed to form a seal around the user’s nose and mouth, che potrebbe non essere il caso con altre maschere di tipo, come per esempio, maschere chirurgiche. I respiratori N95 filtrano la maggior parte delle particelle più grandi 0.06 micron di diametro e quindi, protect from viruses like the coronavirus, che di solito ha un diametro sopra 0.08 Micron.

Che cosa significa N95?

This is the rating of a non-powered filtering respirator that’s “not resistant to oil” and that has a minimum efficiency rating of 95%. What does that mean? This means that less than 5% of particles pass through the mask when tested using sodium chloride aerosol.

Ci sono 3 main types of (non-powered) Air-Purifying Respirators:

  • N (Non-resistant to oil)

  • R (Resistant to oil)

  • P (oil Proof)

Respirator Ratings Comparison

N95KN95FFP2P2Corea 1a ClasseDs
Dove

NOI & Canada

Cina

Europa

Australia & Nuova Zelanda

Corea del sud

Giappone

Specifica
NIOSH-42CFR84
GB2626-2006
IT 149:2001+ A1:2009
AS / NZ 1716:2012
KMOEL 2017-64
Notifica JMHLW 214, 2018

Why Is Testing Needed?

Having personal protective equipment tested by a third-party ensures that products such as Air-Purifying Respirators meet the requirements of the applicable product standards of the country in which they will be used and therefore, that it will not cause harm to the users. As each country’s regulations, and consequently each standard, are different, it is important to inform the third-party agency of which market the product is intended for, when submitting it for evaluation.

What tests are needed for respirators?

For respirators without an exhalation valve, two of the main tests required are: Il Airflow Resistance Test E la Efficienza della filtrazione del particolato (Pfe).

Airflow Resistance Test

The Airflow Resistance test consists of determining the resistance of the mask to inhalation and exhalation. For each determination, the mask is mounted on the test equipment and the air is set to flow at a rate of 85 liters per minute. Respirators must meet the following requirements:

Inhalation Test

Resistance shall not exceed 35 mm water column height pressure

Exhalation Test

Resistance shall not exceed 25 mm water column height pressure

Efficienza della filtrazione del particolato (Pfe)

Pre-Test

  • 20 samples must be tested
  • Per 25 hours prior to the test, samples are conditioned at 85% relative humidity and 38°C

Test Procedure

  • For N-series respirators, a stream of solid sodium chloride particulate aerosol is created with tight constraints on the particle size distribution
  • Il aerosol is neutralized and is conditioned to a temperature of 25℃ and a relative humidity of 30%.
  • Single filter respirators are tested at a continuous airflow rate of 85 litri per minute
  • The efficiency of the filter shall be monitored and recorded throughout the test period by measuring the particle concentration before and after the test sample.
  • The test continues until the minimum efficiency is achieved or until at least 200±5 mg has contacted the filter

Post-Test

  • Masks are classified based on the fraction of sodium chloride that passes through. N95 masks must filter out at least 95% of the NaCl solution, N99 masks filter at least 99% and N100 masks filter at least 99.97%
  • The efficiency measured for each of the 20 samples must be equal to or greater than the filter efficiency criterion (ad es.. 95% for N95).

Per prenotare un test

Clicca qui!

Oppure contattaci all'ora 1 855 346 0444 Per ulteriori informazioni

Servizi aggiuntivi LabTest

Campo giudizi

Campo giudizi

Servizi di valutazione del campo sono un programma di approvazione elettrica progettato per volume basso o attrezzature specializzate dove la certificazione non è il più veloce o più conveniente opzione

Ulteriori informazioni

Servizi di gestione dei sistemi

Servizi di gestione dei sistemi

LabTest certificazione offre formazione, Valutazione, e Certificazione in conformità con ISO 9000 serie di standard per aiutarti a far risaltare la tua attività dalla concorrenza!

Ulteriori informazioni

Unisciti alla nostra community e resta aggiornato con LabTest

Grazie per essere la nostra comunità. Ora fai parte della nostra mailing list. Restate sintonizzati!
Si è verificato un errore durante il tentativo di inviare il messaggio. Inviaci un'e-mail info@labtestcert.com.

I tuoi dati non saranno condivisi con terze parti e utilizzati solo per tenerti informato sulle novità di #8217 con LabTest e il settore.